Purpose: Lung pO2 mapping with (3)He MRI assumes that the sources of signal decay with time during a breath-hold are radiofrequency depolarization and oxygen-dependent T1 relaxation, but the method is sensitive to other sources of spatio-temporal signal change such as diffusion. The purpose of this work was to assess the use of (3)He pO2 mapping in patients with chronic obstructive pulmonary disease.

Methods: Ten patients with moderate to severe chronic obstructive pulmonary disease were scanned with a 3D single breath-hold pO2 mapping sequence.

Results: Images showed signal increasing over time in some lung regions due to delayed ventilation during breath-hold. Regions of physically unrealistic negative pO2 values were seen in all patients, and regional mean pO2 values of -0.3 bar were measured in the two patients most affected by delayed ventilation (where mean time to signal onset was 3-4 s).

Conclusions: Movement of gas within the lungs during breath-hold causes regional changes in signal over time that are not related to oxygen concentration, leading to erroneous pO2 measurements using the linear oxygen-dependent signal decay model. These spatio-temporal sources of signal change cannot be reliably separated at present, making pO2 mapping using this methodology unreliable in chronic obstructive pulmonary disease patients with significant bullous emphysema or delayed ventilation.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.24779DOI Listing

Publication Analysis

Top Keywords

po2 mapping
20
chronic obstructive
16
obstructive pulmonary
16
pulmonary disease
12
delayed ventilation
12
3he po2
8
sources signal
8
signal decay
8
signal change
8
po2 values
8

Similar Publications

Article Synopsis
  • The chapter discusses tumour hypoxia as a newly recognized hallmark of cancer, detailing its various classifications based on aetiology, exposure time, and intensity levels in tumours.
  • It highlights the dual role of hypoxia in cancer, where it can lead to tumour regression (through processes like apoptosis) or promote adaptive progression, suggesting a complex relationship with cancer development.
  • Key advancements in understanding hypoxia are attributed to techniques like polarographic pO microsensors for assessing oxygen levels and the discovery of hypoxia-inducible factors (HIFs), which impact cancer progression on genetic and protein levels and hinder treatment effectiveness.
View Article and Find Full Text PDF

Fluorescence imaging allows for noninvasively visualizing and measuring key physiological parameters like pH and dissolved oxygen. In our work, we created two ratiometric fluorescent microsensors designed for accurately tracking dissolved oxygen levels in 3D cell cultures. We developed a simple and cost-effective method to produce hybrid core-shell silica microparticles that are biocompatible and versatile.

View Article and Find Full Text PDF

An oxygen sensor-mounted fine-needle biopsy tool was used for measurement of oxygen levels in tumor xenografts. The system provides a means of measuring the oxygen content in harvested tumor tissue from specific locations. Oxygen in human tumor xenografts in a murine model was observed for over 1 min.

View Article and Find Full Text PDF

Purpose: This study aimed to develop a biocompatible oximetric electron paramagnetic resonance (EPR) spin probe with reduced self-relaxation, and sensitivity to oxygen for a higher signal-to-noise ratio and longer relaxation times at high oxygen concentration, compared to the reference spin probe OX071.

Procedures: SOX71 was synthesized by succinylation of the twelve alcohol groups of OX071 spin probe and characterized by EPR at X-Band (9.5 GHz) and at low field (720 MHz).

View Article and Find Full Text PDF

Purpose: To demonstrate MR T mapping in vivo as a method to non-invasively estimate vitreous oxygen concentration in ischemic eye disease.

Methods: Patients with ischemic eye disease (central retinal vein occlusion, ocular ischemic syndrome, and proliferative diabetic retinopathy) were prospectively recruited. MRI was performed on each patient before any treatment, with T mapping acquired using an inversion recovery TrueFISP sequence at several inversion times, from a single slice positioned through the center of both eyes in the axial oblique plane.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!