Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To determine the relationships among equivalent intrinsic noise (Neq), sampling efficiency, and contrast sensitivity (CS) in patients with retinitis pigmentosa (RP), where Neq is an estimate of the amount of noise within the visual pathway and sampling efficiency represents the subject's ability to use stimulus information optimally.
Methods: Participants included 10 patients with RP aged 10 to 54 years, who had visual acuities of 20/40 or better, and 10 visually normal control subjects aged 22 to 65 years. CS was measured for 2-cycles-per-degree Gabor patch targets presented in the absence of noise (CS0) and in five levels of noise spectral density. Data were fit with a standard linear amplifier model, which provided estimates of Neq and sampling efficiency.
Results: CS0 for the patients ranged from normal to as much as a factor of 3 below the lower limit of normal. All 10 patients had abnormally high Neq, including two patients with normal CS0. In comparison, only two patients had lower-than-normal sampling efficiency, and these two patients also had below-normal CS0. Log CS0 for the patients was correlated significantly with log Neq (r = -0.80, P < 0.05), but not with log efficiency (r = 0.54, P = 0.11).
Conclusions: Low CS was associated with elevated intrinsic noise in this group of RP patients, but even patients with normal CS had elevated noise levels. The results suggest that CS measurement in both the presence and absence of luminance noise can provide important information about visual dysfunction in RP patients.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3671935 | PMC |
http://dx.doi.org/10.1167/iovs.13-11789 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!