Background: Decreased arterial oxygen pressure obtained at peak exercise is strong evidence of walking-induced hypoxemia, assuming that the lower pressure occurs just before exercise is stopped. Using empirical predefined models and transcutaneous oximetry, we have shown that some patients reporting exercise intolerance show a minimal value at the onset of walking and a post-exercise overshoot. These changes are referred to as transcutaneous "walking-induced transient hacks".

Methods: In 245 patients, walking-induced transcutaneous oxygen pressure changes in the chest were analyzed using observer-independent clustering techniques. Clustering classes were compared to the profile types previously proposed with the cross-correlation technique. The classifications of patients according to both approaches were compared using kappa statistics. In 10 patients showing a hack on transcutaneous oximetry, we analyzed the results of direct iterative arterial sampling recorded during a new walking treadmill test.

Results: Clustering analysis resulted in 4 classes that closely fit the 4 most frequently proposed empirical models (cross-correlation coefficients: 0.93 to 0.97). The kappa between the two classifications was 0.865. In 10 patients showing transcutaneous hacks, the minimal direct arterial oxygen pressure value occurred at exercise onset, and these patients exhibited a recovery overshoot reaching a maximum at two minutes of recovery, confirming the walking-induced transient hypoxemia.

Conclusions: In patients reporting exercise intolerance, transcutaneous oximetry could help to detect walking-induced transient hypoxemia, while peak-exercise arterial oximetry might be normal.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3643941PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0062651PLOS

Publication Analysis

Top Keywords

walking-induced transient
12
oxygen pressure
12
transcutaneous oximetry
12
arterial oxygen
8
patients reporting
8
reporting exercise
8
exercise intolerance
8
patients showing
8
patients
7
transcutaneous
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!