Objectives: While transcatheter aortic valve implantation (TAVI) has rapidly evolved for the treatment of aortic valve disease, the currently used bioprostheses are prone to continuous calcific degeneration. Thus, autologous, cell-based, living, tissue-engineered heart valves (TEHVs) with regeneration potential have been suggested to overcome these limitations. We investigate the technical feasibility of combining the concept of TEHV with transapical implantation technology using a state-of-the-art transcatheter delivery system facilitating the exact anatomical position in the systemic circulation.

Methods: Trileaflet TEHVs fabricated from biodegradable synthetic scaffolds were sewn onto self-expanding Nitinol stents seeded with autologous marrow stromal cells, crimped and transapically delivered into the orthotopic aortic valve position of adult sheep (n = 4) using the JenaValve transapical TAVI System (JenaValve, Munich, Germany). Delivery, positioning and functionality were assessed by angiography and echocardiography before the TEHV underwent post-mortem gross examination. For three-dimensional reconstruction of the stent position of the anatomically oriented system, a computed tomography analysis was performed post-mortem.

Results: Anatomically oriented, transapical delivery of marrow stromal cell-based TEHV into the orthotopic aortic valve position was successful in all animals (n = 4), with a duration from cell harvest to TEHV implantation of 101 ± 6 min. Fluoroscopy and echocardiography displayed sufficient positioning, thereby entirely excluding the native leaflets. There were no signs of coronary obstruction. All TEHV tolerated the loading pressure of the systemic circulation and no acute ruptures occurred. Animals displayed intact and mobile leaflets with an adequate functionality. The mean transvalvular gradient was 7.8 ± 0.9 mmHg, and the mean effective orifice area was 1.73 ± 0.02 cm(2). Paravalvular leakage was present in two animals, and central aortic regurgitation due to a single-leaflet prolapse was detected in two, which was primarily related to the leaflet design. No stent dislocation, migration or affection of the mitral valve was observed.

Conclusions: For the first time, we demonstrate the technical feasibility of a transapical TEHV delivery into the aortic valve position using a commercially available and clinically applied transapical implantation system that allows for exact anatomical positioning. Our data indicate that the combination of TEHV and a state-of-the-art transapical delivery system is feasible, representing an important step towards translational, transcatheter-based TEHV concepts.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ejcts/ezt243DOI Listing

Publication Analysis

Top Keywords

aortic valve
24
anatomically oriented
12
marrow stromal
12
valve position
12
transcatheter aortic
8
valve
8
valve implantation
8
stromal cell-based
8
tissue-engineered heart
8
heart valves
8

Similar Publications

Background: Delirium is associated with patient prognosis after transcatheter aortic valve implantation (TAVI). However, the prognostic impact of subsyndromal delirium, described as an intermediate stage between delirium and normal cognition, is uncertain. The present study aimed to investigate the prognostic impact of delirium severity in patients undergoing TAVI.

View Article and Find Full Text PDF

Clinical Outcomes after Transcatheter Aortic Valve Implantation in Nonagenarian Patients: a Retrospective Population-Based Cohort Study.

Ann Epidemiol

January 2025

IRCCS Centro Cardiologico Monzino, Department of Cardiovascular Surgery, 20138 Milan, Italy; Department of Biomedical, Surgical and Dental Sciences, University of Milan, 20100 Milan, Italy.

Purpose: To compare the overall survival and the risk of all-cause and heart failure-specific hospitalization in nonagenarian patients hospitalized for symptomatic severe aortic stenosis (AS) who underwent transcatheter aortic valve implantation (TAVI) or conservative treatment.

Methods: Population-based retrospective cohort study based on healthcare utilization databases of the Italian region of Lombardy. The cohort included all nonagenarians hospitalized for AS between 2017 and 2021, who underwent TAVI within 90 days from first diagnosis or conservative treatment.

View Article and Find Full Text PDF

Introduction And Importance: Severe aortic stenosis (AS) and chronic obstructive pulmonary disease (COPD) significantly increase perioperative morbidity and mortality. This case report discusses the challenges of managing a 75-year-old male patient with severe AS and advanced COPD undergoing elective abdominal aortic aneurysm (AAA) repair.

Case Presentation: The patient presented with a 6.

View Article and Find Full Text PDF

Reversed valved Potts shunt for refractory primary pulmonary arterial hypertension.

Multimed Man Cardiothorac Surg

January 2025

• Pediatric and Congenital Cardiac Surgery, LMU University Hospital, Munich, Germany • Congenital Cardiac Surgery, German Heart Center Munich, Munich, Germany • European Pediatric Heart Center EKHZ Munich, Munich, Germany.

This procedure is carried out via a full sternotomy using standard aortic and bicaval cannulations. For the aortic and pulmonary anastomoses, selective antegrade unilateral cerebral perfusion is used after cooling the body temperature to 26 °Celsius. A 12-mm Hancock conduit is interposed between the pulmonary artery and the proximal descending aorta using standard running suture techniques.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!