The purpose of this study was to compare two different styles of prostate IGRT: bony landmark (BL) setup vs. fiducial markers (FM) setup. Twenty-nine prostate patients were treated with daily BL setup and 30 patients with daily FM setup. Delivered dose distribution was reconstructed on cone-beam CT (CBCT) acquired once a week immediately after the alignment. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed 1 cm safety margin. Alternative plans assuming smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with initial ones. While the margin reduction in case of BL setup makes the prostate coverage significantly worse (p = 0.0003, McNemar's test), in case of FM setup with the reduced 7 mm margin, the prostate coverage is even better compared to BL setup with 10 mm margin (p = 0.049, Fisher's exact test). Moreover, partial volumes of organs at risk irradiated with a specific dose can be significantly lowered (p < 0.0001, unpaired t-test). Reducing of safety margin is not acceptable in case of BL setup, while the margin can be lowered from 10 mm to 7 mm in case of FM setup.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5714424PMC
http://dx.doi.org/10.1120/jacmp.v14i3.4203DOI Listing

Publication Analysis

Top Keywords

case setup
16
setup
11
dose distribution
8
bony landmark
8
landmark setup
8
fiducial markers
8
markers setup
8
daily setup
8
safety margin
8
prostate coverage
8

Similar Publications

The current study investigated the geometry, design and solid angle impacts on full energy peak efficiency (FEPE) of NaI(Tl) detectors for a line source. A line source is fabricated using 99mTc solution filled in a borosilicate glass tube of inner diameter 3 mm, tube wall thickness 2.5 mm and length 12.

View Article and Find Full Text PDF

Introduction: Large administrative healthcare databases can be used for near real-time sequential safety surveillance of drugs as an alternative approach to traditional reporting-based pharmacovigilance. The study aims to build and empirically test a prospective drug safety monitoring setup and perform a sequential safety monitoring of rofecoxib use and risk of cardiovascular outcomes.

Methods: We used Danish population-based health registers and performed sequential analysis of rofecoxib use and cardiovascular outcomes using case-time-control and cohort study designs from January 2000 to September 2004.

View Article and Find Full Text PDF

Selective activity of Tabebuia avellanedae against Giardia duodenalis infecting organoid-derived human gastrointestinal epithelia.

Int J Parasitol Drugs Drug Resist

January 2025

Department of Infectious Diseases, Unit of Foodborne and Neglected Parasitic Diseases, Istituto Superiore di Sanità, viale Regina Elena 299, Rome, Italy. Electronic address:

Giardia duodenalis is a widespread intestinal protozoan that affects mammals, including humans. Symptoms can range from being subclinical to causing severe abdominal pain and diarrhoea. Giardiasis often requires repeated treatment with synthetic drugs like metronidazole.

View Article and Find Full Text PDF

Wearable motion capture gloves enable the precise analysis of hand and finger movements for a variety of uses, including robotic surgery, rehabilitation, and most commonly, virtual augmentation. However, many motion capture gloves restrict natural hand movement with a closed-palm design, including fabric over the palm and fingers. In order to alleviate slippage, improve comfort, reduce sizing issues, and eliminate movement restrictions, this paper presents a new low-cost data glove with an innovative open-palm and finger-free design.

View Article and Find Full Text PDF

Although cone-beam computed tomography (CBCT) is the predominant cross-sectional imaging modality used by interventional radiologists, advancements in hybrid angiography-computed tomography (Angio-CT) technology have demonstrated a strong potential for increased utilization in the angiography suite. The benefits of increased workflow efficiency, decreased relative cost, multipurpose utility, and most importantly improved patient care, may encourage institutions to accept the higher upfront cost of Angio-CT rooms for potential long-term benefits. Hybrid Angio-CT setups are less prone to motion and streak artifacts and may provide superior image quality compared to CBCT.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!