A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessment of the integrity of compounds stored in assay-ready plates using a kinase sentinel assay. | LitMetric

Sentinel assays are a convenient adjunct to LC-MS purity assessment to monitor the integrity of compounds in pharmaceutical screening collections over time. To assess the stability of compounds stored both at room temperature and at -20°C in assay-ready plates that were either vacuum pack-sealed using a convenient industrial vacuum sealing method or individually sealed using conventional foil seals, a diverse collection of ~ 5,000 compounds was assayed using a robust biochemical kinase assay at intervals over a one year period. Assay results at each time point were compared to those of initial assay using a series of correlations of compound Percent of Control (POC) values as well as IC50 values of a subset of compounds in 200 nL or 500 nL plates. The fraction of hits in common between initial assays and assays at later time points ranged from 82% to 95% over one year and remained relatively constant over time with all storage temperatures or sealing methods tested. A majority of the hits that exhibited a consistent gradual trend to lower potency over one year storage were shifted to lower potency upon the rapid removal of DMSO solvent. Compound precipitation rather than compound decomposition is the likely reason for trends to lower potency for most such compounds over the storage period. Plates stored at room temperature featured a significantly higher fraction of hits that exhibited a trend to lower apparent potency than those stored at -20°C suggesting that this lower temperature is preferable for longer-term storage.

Download full-text PDF

Source
http://dx.doi.org/10.2174/13862073113169990145DOI Listing

Publication Analysis

Top Keywords

lower potency
12
integrity compounds
8
compounds stored
8
assay-ready plates
8
stored room
8
room temperature
8
fraction hits
8
hits exhibited
8
trend lower
8
compounds
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!