Background: Radiologic determination of pediatric femoral fracture rotation has been debated. Measuring the antetorsion angle of the fractured femur by computed tomography and comparing it with the opposite side has been the method of choice for this purpose. However, no simple method for direct measurement of femoral fracture rotation exists in the literature. In this study, our aim was to test a mathematical method of measuring the axial plane malrotation from direct roentgenograms.

Materials And Methods: A pediatric femoral shaft fracture model was produced. The bone was secured to a wooden frame that allowed the distal part of the fracture to rotate around an axis. Radiographs were taken at known intervals of rotation ranging from the neutral position to 60° external rotation and to 60° internal rotation in 5° increments of rotation. Five independent, blinded observers measured the radiographs and calculated the fracture rotation according to a standard formula. Calculated rotation values were compared with known rotation values.

Results: Calculated rotation values were close to actual rotation values throughout the arc of rotation. The mean absolute error of five observers for all measurements of external and internal rotation was 3.97° (±0.83). The correlation coefficient between calculated and actual rotation values was 0.9927. The interobserver intraclass correlation coefficient for calculated rotation was 0.997.

Conclusions: Absolute error and correlation coefficient values indicate that this method is accurate and reliable in determining the fracture rotation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3828500PMC
http://dx.doi.org/10.1007/s10195-013-0244-0DOI Listing

Publication Analysis

Top Keywords

fracture rotation
20
rotation
17
rotation values
16
pediatric femoral
12
femoral fracture
12
calculated rotation
12
correlation coefficient
12
internal rotation
8
actual rotation
8
absolute error
8

Similar Publications

Background: Untreated cubitus varus results in cosmetic deformity as well as posterolateral rotatory instability at the elbow if longstanding. French osteotomy with its modifications is the most commonly done osteotomy and relies on a medial intact hinge and these osteotomies fail to address the lateral prominence. Intraoperative fixator assistance to adjust the translation and fine tune the osteotomy is a novel method to address the lateral prominence.

View Article and Find Full Text PDF

In the face of challenges encountered during femur fracture surgery, such as the high rates of malalignment and X-ray exposure to operating personnel, robot-assisted surgery has emerged as an alternative to conventional state-of-the-art surgical methods. This paper introduces the development of a leader-follower robot-assisted system for femur fracture surgery, called Robossis. Robossis comprises a 7-DOF haptic controller and a 6-DOF surgical robot.

View Article and Find Full Text PDF

Novel 'mini-incision' metacarpal fixation technique for long oblique and spiral shaft fractures.

JPRAS Open

March 2025

Plastic & Reconstructive Surgery Department, Prince Sultan Military Medical City, Riyadh, Saudi Arabia.

Background: Metacarpal shaft fractures account for 30 % of all hand fractures, and long oblique and spiral shaft fractures represent a significant quantity. Closed or open reduction and internal fixation is generally indicated for unstable fractures, rotational malalignment or significant metacarpal shortening. Various techniques can achieve appropriate fixation, though no single technique has been proven to be superior across all cases.

View Article and Find Full Text PDF

Objective: To compare the efficacy of three treatment methods for older adult patients with osteoporotic proximal humerus fractures: proximal humerus locking plate (PHILOS) combined with calcium sulfate injection, PHILOS plate alone, and artificial hemi-shoulder joint replacement.

Methods: The clinical data of 48 older adult patients with osteoporotic proximal humerus fractures admitted to the Shoulder and Elbow Surgery Department of Zhongshan Hospital Affiliated with Dalian University from February 2018-August 2021 were retrospectively analyzed. The patients comprised 18 males and 30 females, with a mean age of (68.

View Article and Find Full Text PDF

Reliability of unicortical plate fixation for metacarpal shaft fractures: A preliminary clinical report with short-term follow-up.

Ann Chir Plast Esthet

January 2025

Department of Plastic and Reconstructive Surgery, Dongtan Sacred Heart Hospital, Hallym University College of Medicine, Hwaseong, Republic of Korea.

Background: Unicortical plate fixation offers several theoretical advantages in the treatment of metacarpal shaft fractures compared to bicortical fixation. This approach avoids the potential hazard of excessive drilling into the volar cortex, thus minimizing damage to surrounding soft tissues and helping prevent complications related to improperly sized screws. These benefits prompted our team to conduct a preliminary clinical study to investigate the effectiveness and safety of this approach.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!