During application of high intensity focused ultrasound (HIFU) with therapy arrays, the existence of grating lobes can cause heating at unintended tissue regions. Therefore, the reduction of grating lobes in therapeutic arrays is an important goal. One way to reduce the grating lobes in therapy arrays is to excite the arrays with broadband signals (defined here as >10% fractional bandwidth). To achieve a reduction in grating lobe levels in an ultrasonic array, coded waveforms can be utilized that reduce the grating lobe levels while maintaining the spatial peak temporal average intensity. In this study, a 5-MHz, 9-element, 1.25 mm inter-elemental spacing linear array was excited by a sinusoidal waveform, a conventional linear chirp, and a modified linear chirp. Both chirps spanned the -3-dB bandwidth of the transducer. The conventional chirp was a broadband signal with a linear sweep of frequencies between 2.5 and 7.5 MHz, with all frequency components excited with equal amplitude. The modified chirp signal also swept the frequencies between 2.5 and 7.5 MHz, but the amplitude was weighted such that the edges (low and high frequencies of the band) were excited with more energy than the center of the band. In simulations, the field patterns for the sinusoidal, conventional chirp and modified chirp excitations were produced from the array using Field II and compared. For experiments, the beam pattern from a 5-MHz single-element transducer was mapped using a hydrophone for the sinusoidal, conventional chirp and modified chirp excitation. Each field from the transducer was repeated and summed to produce a field from an array of 9 elements. The difference in the time averaged intensity (in dB) in the main lobe and grating lobes were estimated for each excitation and compared. The results demonstrated that the chirp signals resulted in decreases in grating lobe levels compared to the main lobe, i.e. 10 dB down for focusing and 6 dB down for focusing and steering. A further 1 dB decrease in grating lobe levels was observed for the modified chirp excitation compared to the conventional chirp excitation, which corresponds to ~21% reduction in energy deposition at the grating lobe location.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3674191 | PMC |
http://dx.doi.org/10.1016/j.ultras.2013.03.014 | DOI Listing |
In this work, a specially designed multilayer indium tin oxide (ITO) mesh structure metasurface was proposed as a microwave absorber, achieving both excellent angle-insensitive broadband absorption and high shielding effectiveness (SE). It features gradually changing surface resistance ( ), to expand the absorption bandwidth while maintaining high SE. Also, a folded square ring metasurface was designed to effectively suppress surface wave grating lobes, as well as to reduce the unit size of the metasurface and thus the absorber.
View Article and Find Full Text PDFUltrasonics
January 2025
School of Biological Science and Medical Engineering, Beihang University, Beijing, China. Electronic address:
Transcranial focused ultrasound (tFUS) has been gaining increased attention as a non-invasive modality for treating brain diseases. However, accurately focusing on brain structures remains a challenge as the ultrasound is severely distorted by the presence of the skull. In this article, we propose a promising distortion correction method based on spherical wave expansions.
View Article and Find Full Text PDFNanophotonics
January 2024
State Key Laboratory for Modern Optical Instrumentation, Center for Optical & Electromagnetic Research, College of Optical Science and Engineering, International Research Center for Advanced Photonics, Zhejiang University, Zijingang Campus, Hangzhou 310058, China.
An optical phased array (OPA) with 2-D circular sparse array aperture has been proposed and demonstrated in the silicon integrated photonic platform. The sparse distribution of the antenna array can realize no grating lobes in 2-D full field of view (FOV). To achieve fast and accurate phase calibration for OPA, an improved rotating element electric field vector algorithm based on golden section search method (GSS-REV) has also been proposed and verified.
View Article and Find Full Text PDFMicromachines (Basel)
November 2024
Research Center for Novel Computing Sensing and Intelligent Processing, Zhejiang Lab, Hangzhou 311100, China.
Ultrasonics
February 2025
School of Information Science and Technology, Fudan University, Shanghai 200433, China.
In Lamb wave imaging based on a phased array, higher frequencies narrowband excitation pulses enable more precise damage detection and localization. However, due to the size constraints of individual transducer elements, the spacing between array elements may exceed half the wavelength of the excitation signal. This can lead to a grating lobe effect.