A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Translation and validation of the wound-specific quality of life instrument Cardiff Wound Impact Schedule in a Swedish population. | LitMetric

Purpose: To translate and validate the wound-specific health-related quality of life instrument, the Cardiff Wound Impact Schedule (CWIS) in a Swedish population.

Methods: The instrument was first translated into Swedish, using the Standard Linguistic Validation Process. The Swedish version of the CWIS was then tested for its psychometric properties in a Swedish context. A total of 117 patients with acute and hard-to-heal wounds were included. The patients were asked to fill in the Swedish version of the CWIS and the generic instrument SF-36 at baseline and after 1 week. Patients with acute wounds were also asked to fill in both instruments after 6 weeks.

Results: Face validity and content validity were assessed by patients and an expert group, and judged as good. Criterion validity was calculated with correlation between CWIS and SF-36, reaching moderate to high values. Reliability of the three domains of the CWIS measured with internal consistency and test-retest stability was acceptable to excellent. Internal responsiveness was assessed with standardised response mean and showed moderate to high sensitivity.

Conclusions: This study concludes that the Swedish version of CWIS is a valid and reliable tool for measuring health-related quality of life in patients with acute and hard-to-heal wounds.

Download full-text PDF

Source
http://dx.doi.org/10.1111/scs.12050DOI Listing

Publication Analysis

Top Keywords

quality life
12
swedish version
12
version cwis
12
patients acute
12
life instrument
8
instrument cardiff
8
cardiff wound
8
wound impact
8
impact schedule
8
health-related quality
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!