Unicompartmental knee arthroplasty (UKA) allows replacement of a single compartment in patients with limited disease. However, UKA is technically challenging and relies on accurate component positioning and restoration of natural knee kinematics. This study examined the accuracy of dynamic, real-time ligament balancing using a robotic-assisted UKA system. Surgical data obtained from the computer system were prospectively collected from 51 patients (52 knees) undergoing robotic-assisted medial UKA by a single surgeon. Dynamic ligament balancing of the knee was obtained under valgus stress prior to component implantation and then compared to final ligament balance with the components in place. Ligament balancing was accurate up to 0.53 mm compared to the preoperative plan, with 83% of cases within 1 mm at 0°, 30°, 60°, 90°, and 110° of flexion. Ligamentous laxity of 1.31 ± 0.13 mm at 30° of flexion was corrected successfully to 0.78 ± 0.17 mm (P < 0.05). Robotic-assisted UKA allows accurate and precise reproduction of a surgical balance plan using dynamic, real-time soft-tissue balancing to help restore natural knee kinematics, potentially improving implant survival and functional outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3619543PMC
http://dx.doi.org/10.1155/2013/837167DOI Listing

Publication Analysis

Top Keywords

ligament balancing
16
balancing robotic-assisted
8
unicompartmental knee
8
knee arthroplasty
8
uka allows
8
natural knee
8
knee kinematics
8
dynamic real-time
8
robotic-assisted uka
8
ligament
5

Similar Publications

Purpose: This study reports the relationship between posterior cruciate ligament (PCL) retention vs resection and soft tissue laxity and balance throughout flexion using a robotically controlled ligament tensioner.

Methods: 55 robotic-assisted TKAs (Total knee arthroplasty) were retrospectively reviewe. The robotic ligament tensioner collected laxity data both before and after PCL resection.

View Article and Find Full Text PDF

Background: This is a novel rat study using native peptide therapy, focused on reversing quadriceps muscle-to-bone detachment to reattachment and stable gastric pentadecapeptide BPC 157 per-oral therapy for shared muscle healing and function restoration.

Methods: Pharmacotherapy recovering various muscle, tendon, ligament, and bone lesions, and severed junctions (i.e.

View Article and Find Full Text PDF

: Up to 27% of anterior cruciate ligament (ACL) reconstruction cases result in a residual positive pivot shift sign, indicating anteroposterior and rotational instability. This instability can compromise returning to sports and increase the risk of further injuries. The biomechanical role of the anterolateral ligament (ALL) in controlling internal knee rotation is well known.

View Article and Find Full Text PDF

Can robotic arm-assisted total knee arthroplasty be applied to valgus deformity.

Arch Orthop Trauma Surg

January 2025

Department of Orthopaedic Surgery, University Hospital centre (Saint Etienne), Avenue Albert Raimond, Saint-priest-en-Jarez, 42270, France.

Introduction: Total knee arthroplasty (TKA) in valgus knees is challenging. Optimal ligament balance, implant neutral or moderate valgus alignment are crucial but conventional instrumentations usually lead to outliers. Robotic arm assisted TKA (RATKA) advantages could answer this challenge.

View Article and Find Full Text PDF

Objective: Robotic-assisted total knee arthroplasty (TKA) is a novel orthopedic technique. The workflow of robotic-assisted TKA is quite different from that of traditional manual TKA and may result incompletely different resection parameters. Understanding these parameters may help surgeons better perform robotic-assisted TKA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!