Background: Nebuliser systems are used to deliver medications to control the symptoms and the progression of lung disease in people with cystic fibrosis. Many types of nebuliser systems are available for use with various medications; however, there has been no previous systematic review which has evaluated these systems.
Objectives: To evaluate effectiveness, safety, burden of treatment and adherence to nebulised therapy using different nebuliser systems for people with cystic fibrosis.
Search Methods: We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register comprising references identified from comprehensive electronic database searches, handsearching of relevant journals and abstract books of conference proceedings. We searched the reference lists of each study for additional publications and approached the manufacturers of both nebuliser systems and nebulised medications for published and unpublished data. Date of the most recent search: 15 Oct 2012.
Selection Criteria: Randomised controlled trials or quasi-randomised controlled trials comparing nebuliser systems including conventional nebulisers, vibrating mesh technology systems, adaptive aerosol delivery systems and ultrasonic nebuliser systems.
Data Collection And Analysis: Two authors independently assessed studies for inclusion. They also independently extracted data and assessed the risk of bias. A third author assessed studies where agreement could not be reached.
Main Results: The search identified 40 studies with 20 of these (1936 participants) included in the review. These studies compared the delivery of tobramycin, colistin, dornase alfa, hypertonic sodium chloride and other solutions through the different nebuliser systems. This review demonstrates variability in the delivery of medication depending on the nebuliser system used. Conventional nebuliser systems providing higher flows, higher respirable fractions and smaller particles decrease treatment time, increase deposition and may be preferred by people with CF, as compared to conventional nebuliser systems providing lower flows, lower respirable fractions and larger particles. Nebulisers using adaptive aerosol delivery or vibrating mesh technology reduce treatment time to a far greater extent. Deposition (as a percentage of priming dose) is greater than conventional with adaptive aerosol delivery. Vibrating mesh technology systems may give greater deposition than conventional when measuring sputum levels, but lower deposition when measuring serum levels or using gamma scintigraphy. The available data indicate that these newer systems are safe when used with an appropriate priming dose, which may be different to the priming dose used for conventional systems. There is an indication that adherence is maintained or improved with systems which use these newer technologies, but also that some nebuliser systems using vibrating mesh technology may be subject to increased failures.
Authors' Conclusions: Clinicians should be aware of the variability in the performance of different nebuliser systems. Technologies such as adaptive aerosol delivery and vibrating mesh technology have advantages over conventional systems in terms of treatment time, deposition as a percentage of priming dose, patient preference and adherence. There is a need for long-term randomised controlled trials of these technologies to determine patient-focused outcomes (such as quality of life and burden of care), safe and effective dosing levels of medications and clinical outcomes (such as hospitalisations and need for antibiotics) and an economic evaluation of their use.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/14651858.CD007639.pub2 | DOI Listing |
Comb Chem High Throughput Screen
January 2025
Baoying People's Hospital, Yangzhou 225800, China.
Shuanghuanglian (SHL) and its primary constituents have demonstrated protective effects against allergenic diseases. This review examines the anaphylactic and anti-allergenic activities of SHL and its constituents. We also discuss potential avenues for future research, particularly regarding the expansion of the clinical applications of SHL formulations (oral or nebulized) for the treatment of allergenic disorders.
View Article and Find Full Text PDFNat Commun
January 2025
Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, CA, USA.
Amidst the rising prevalence of respiratory diseases, the importance of effective lung treatment modalities is more critical than ever. However, current drug delivery systems face significant limitations that impede their efficacy and therapeutic outcome. Biohybrid microrobots have shown considerable promise for active in vivo drug delivery, especially for pulmonary applications via intratracheal routes.
View Article and Find Full Text PDFTurk Arch Pediatr
January 2025
Department of Pediatric Pulmonology, Marmara University School of Medicine, İstanbul, Türkiye.
Objective: Nebulizer contamination has potential harmful effects on the respiratory system. The aim was to investigate the contamination profile of the nebulizers in cystic fibrosis patients and evaluate the relationship between hygiene practices and microbial contamination. Materials and Methods: Microbiological swab samples were taken from 3 different locations of the nebulizers of 102 patients.
View Article and Find Full Text PDFBMC Anesthesiol
January 2025
Department of Anesthesiology, Loma Linda University Medical Center, Loma Linda, CA, USA.
Post-dural puncture headache (PDPH) is a debilitating complication of neuraxial anesthesia, particularly prevalent in obstetric patients, usually characterized by a postural headache. PDPH is hypothesized to result from cerebrospinal fluid leakage through a dural puncture, triggering symptoms like neck stiffness and subjective hearing changes. While conservative measures are common for treatment, more refractory cases may require invasive interventions such as an epidural blood patch (EBP).
View Article and Find Full Text PDFBMJ
December 2024
Division of Pharmacoepidemiology and Pharmacoeconomics, Department of Medicine, Brigham and Women's Hospital, Boston, MA 02120, USA.
Objective: To compare the effectiveness and safety of budesonide-glycopyrrolate-formoterol, a twice daily metered dose inhaler, and fluticasone-umeclidinium-vilanterol, a once daily dry powder inhaler, in patients with chronic obstructive pulmonary disease (COPD) treated in routine clinical practice.
Design: New user cohort study.
Setting: Longitudinal commercial US claims data.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!