Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: In accordance with Boyle's law (as barometric pressure decreases, gas volume increases), thoracostomy is often recommended for patients with pneumothoraces before helicopter EMS (HEMS) transport. We sought to characterize altitude-related volume changes in a pneumothorax model, aiming to improve clinical decisions for preflight thoracostomy in HEMS patients.
Methods: This prospective study used 3 devices to measure air expansion at HEMS altitudes. The main device was an artificial pneumothorax model that mimicked a human pulmonary system with a 40 mL pneumothorax. In addition, volume changes were calculated in 2 spherical balloons (6 L and 25 L) by measuring equatorial circumferences. Measurements were recorded at 500-foot altitude increments from 1000 to 5000 feet above ground level.
Results: The 3 models exhibited volume increases of 12.7%-16.2% at 5000 feet compared to ground level. Univariate linear regression yielded similar increases, 1.27%-1.52%, in volume per 500-foot altitude increase for all 3 models. Bivariate indexed linear regression identified no association between volume increase and assessment model (P values .19 and .29). Locally weighted scatterplot smoothing (lowess) plots indicated linearity of the altitude-volume relationship.
Conclusion: This study demonstrated predictable pneumothorax volume changes at typical HEMS altitudes. Increased understanding of altitude-related volume changes will aid decision making before transport.