A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biomechanical comparison of a locking plate with intraplate compression screw versus locking plate with plantar interfragmentary screw for Lapidus arthrodesis: a cadaveric study. | LitMetric

Lapidus arthrodesis (first metatarsal cuneiform arthrodesis) has become an accepted procedure for hallux abducto valgus. Several variations of fixation have been described. Earlier weightbearing postoperatively has been one reported benefit of using locking plates for fixation. Additionally, studies have demonstrated that fixation placed on the plantar or tension side of the arthrodesis increases the biomechanical advantage. We performed a biomechanical cadaveric study of the Lapidus procedure, comparing a previously reported technique using a low profile locking plate with an intraplate compression screw versus the same locking plate with a plantar interfragmentary screw (PIFS) placed on the tension side of the arthrodesis in 10 fresh, paired, cadaver limbs. The mean ultimate load of the plate with a PIFS was 383.2 ± 211.5 N, and the mean ultimate load of the plate with an intraplate compression screw was 205.5 ± 97.2 N. The mean ultimate load of the LPS Lapidus plate with a PIFS was statistically greater (p = .027) than that with the plate intraplate compression screw. Our results indicated that changing the orientation of the compression screw to a PIFS significantly increased the stability of the Lapidus arthrodesis fixation construct. The modified construct with the PIFS might decrease the incidence of nonunion and, ultimately, allow patients to bear weight faster postoperatively.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.jfas.2013.02.012DOI Listing

Publication Analysis

Top Keywords

compression screw
20
locking plate
16
plate intraplate
16
intraplate compression
16
lapidus arthrodesis
12
ultimate load
12
plate
8
screw versus
8
versus locking
8
plate plantar
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!