Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: The original bony lid technique involves removing window of cortical bone using a microsaw, removing a failing implant through the window, and then replacing the bone into its original position. The purpose of this case series was to present modifications to the bony lid technique to improve outcomes.
Materials And Methods: Ten patients (9 men and 1 woman) aged between 47 and 89 years were treated during a 5-year period with modifications to the bony lid technique. Modifications to the bony lid technique included restricting the size of the bony lid, use of a long shank drill, performing guided bone regeneration, immediate implant placement, and providing rigid fixation.
Results: No complications occurred in the 10 cases presented in this case series. An immediate implant placement procedure was performed in 3 of the 10 patients treated. Fixation screws and a microplate were used to fix the bony lid in 1 patient. Allogenic bone was used in another case. Additional trephine and thin drills were used in 2 cases in the mandibular molar area.
Conclusions: Replacing failing dental implants can be successfully accomplished by removing cortical bone on the buccal aspect of the implant and then replacing this bone after the implant is removed or replaced. Using allogenic bone, fixation screws, microplates, and thin drills can help facilitate the success of this procedure.