Purpose: To compare Nd:YAG laser rates following implantation of AcrySof(®) SN60WF (Alcon), Akreos(®) AO-MI60 (Baush & Lomb), and Hoya(®) YA-60BB (Hoya) intraocular lenses.

Methods: This retrospective study was conducted at three French centers with each implanting at least two of the three implants. Included patients had undergone uncomplicated cataract surgery with at least 3 years of follow-up. Records of patients implanted with one of the three IOL's were drawn randomly from the surgical logs. Postoperative data were obtained from the medical records of either the surgeon or the referring physician. Time elapsing until Nd:YAG laser was analysed using Kaplan-Meier survival curves.

Results: Three hundred eyes were implanted (AcrySof(®) 126, Akreos(®) 89, and Hoya(®) 85). AcrySof(®) recipients were the youngest (AcrySof(®) 72.1, Akreos(®) 76.4, and Hoya(®) 75.2 years of age: P=0.0007). The sex ratio was 4:6 male:female. Follow-up was longest for Hoya eyes (AcrySof(®) 29.4, Akreos(®) 24.6 and Hoya(®) 34.6 months; P=0.0002). Eyes implanted with AcrySof(®) had 1.74 times less chance of Nd:YAG laser treatment than Hoya eyes (P=0.0327) and 3.50 times less than Akreos(®) eyes (P<0.0001). The results remained unchanged when the analysis was restricted to events in the first 24 months (Risk Ratios: Hoya(®)=2.64: P=0.02; and Akreos(®)=4.22: P=0.0001). Adjustment on unbalanced confounding variables did not alter the results.

Conclusions: Eyes with AcrySof(®) implants required significantly fewer Nd:YAG laser capsulotomies than those with Hoya(®) and Akreos(®) implants and were therefore less subject to Nd:YAG laser treatment complications, thus ensuring better vision at the lowest cost.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jfo.2012.07.008DOI Listing

Publication Analysis

Top Keywords

ndyag laser
16
laser rates
8
rates implantation
8
implantation acrysof®
8
acrysof® sn60wf
8
akreos® ao-mi60
8
hoya® ya-60bb
8
eyes implanted
8
implanted acrysof®
8
hoya eyes
8

Similar Publications

Treatment of onychomycosis includes topical and systemic agents. However, prolonged use of oral treatment could cause adverse effects and topical antifungal agents have limited penetration. To compare the clinical efficacy and the safety of fractional CO laser combined with topical tioconazole nail solution versus Q-switched 1064 Nd: YAG laser in the treatment of fingernail onychomycosis.

View Article and Find Full Text PDF
Article Synopsis
  • Melasma is a common, chronic skin condition that mainly affects women, presenting as dark patches on the face and is often perceived as a serious cosmetic issue.
  • A survey conducted among 199 dermatologists in Turkiye revealed that the majority of patients with melasma are females between the ages of 30 to 40, with mixed melasma being the most common type.
  • The study found that topical treatments, particularly Kligman's formula, are most frequently used, while oral treatments like tranexamic acid are less common, and there's a significant recurrence rate of 41%-60%, suggesting the need for better management strategies.
View Article and Find Full Text PDF

Anion photoelectron spectra of ThSO- and ThS2- were recorded using the third (355 nm) harmonic of an Nd-YAG laser; these provided the measured vertical detachment energies of each anion. The experiments are supported by extensive coupled cluster calculations on ThSO, ThSO-, ThS2, and ThS2-, as well as the oxygen congeners ThO2 and ThO2-. The ab initio calculations, which included complete basis set extrapolations, spin-orbit effects using four-component coupled cluster, and higher-order correlation contributions through CCSDT(Q), yielded an adiabatic electron affinity for ThO2 that was within 0.

View Article and Find Full Text PDF

Plasma focus devices represent a class of hot and dense plasma sources that serve a dual role in fundamental plasma research and practical applications. These devices allow the observation of various phenomena, including the z-pinch effect, nuclear fusion reactions, plasma filaments, bursts, shocks, jets, X-rays, neutron pulses, ions, and electron beams. In recent years, considerable efforts have been directed toward miniaturizing plasma focus devices, driven by the pursuit of both basic studies and technological advancements.

View Article and Find Full Text PDF
Article Synopsis
  • The study looked at the risks of retinal detachment (RD) after a specific eye surgery called Boston Type 1 Keratoprosthesis (B1KPro) during the first year and beyond.
  • They found that 29% of patients experienced RD, with most cases happening within the first year (21%) and fewer later (7%).
  • Important risk factors for early RD included low eye pressure (hypotony), previous eye surgeries, and certain eye conditions, while changes in the retina before surgery were linked to later RD.
View Article and Find Full Text PDF