Objectives: Clinical studies to assess dental implants are common in implantology, but such studies are usually performed for specific indications and following a specific protocol with strict inclusion and exclusion criteria. The aim of the current study was to evaluate the Straumann Bone Level SLActive dental implant in a prospective, multicenter, noninterventional trial.

Method And Materials: The implant could be used in whatever manner was deemed suitable by the clinician, within approved indications. No particular placement or loading protocol was specified. A total of 1,532 implants were placed in 852 patients in 123 centers in nine countries in the US and Europe. After exclusion of three countries due to patient enrollment and data issues, 759 patients with 1,355 implants were analyzed.

Results: Most patients received one or two implants (58.6% and 25.3% of patients, respectively), and 90% of cases were performed with a raised flap. A submerged healing protocol was significantly more prevalent in European centers, while transmucosal healing was significantly more prevalent in North American centers. After 1 year, 538 patients with 908 implants were available for evaluation. The cumulative implant survival and success rates were 98.5% and 96.0%, respectively.

Conclusions: This prospective noninterventional study evaluated the use of Straumann Bone Level SLActive dental implants in a large number of patients. The cumulative survival and success rates were similar to those observed in controlled clinical trials, confirming this dental implant's clinical applicability in daily practice.

Download full-text PDF

Source
http://dx.doi.org/10.3290/j.qi.a29611DOI Listing

Publication Analysis

Top Keywords

straumann bone
12
bone level
12
level slactive
12
slactive dental
12
prospective noninterventional
8
noninterventional study
8
dental implant
8
dental implants
8
survival success
8
success rates
8

Similar Publications

Effect of high trimline aligners on distalizing mandibular molars: a three-dimensional finite element study.

Eur J Med Res

December 2024

Urumql DW Innovation InfoTech Co., Ltd., Xinjiang, China.

Objective: The primary focus of this investigation was to evaluate the biomechanical effects of high trimline design aligners on the distalization of mandibular molars, employing three-dimensional finite element analysis (3D-FEA). The study concentrated on aspects such as tooth movement, stress distribution, and anchorage control.

Methods: Utilizing Cone-beam computed tomography (CBCT) data, a detailed 3D geometrical model was constructed for finite element analysis.

View Article and Find Full Text PDF

This case report aims to report the successful use of a short-splinted implant in a patient with a history of periodontal disease. Two implants were used to rehabilitate severe atrophied alveolar ridge with fixed prosthesis. Despite the left posterior ridge being weakened by maxillary sinus pneumatization and bone remodeling after tooth extraction, no bone grafts nor sinus osteotomy procedures were needed for the rehabilitation surgery.

View Article and Find Full Text PDF

Primary Stability of Zirconia Dental Implants with Cylindrical and Tapered Designs Across Varying Bone Densities: An In Vitro Evaluation.

Dent J (Basel)

November 2024

Department of Oral Surgery and Oral Medicine, Faculdade de Medicina Dentária da Universidade de Lisboa, 1600-277 Lisbon, Portugal.

While titanium implants are widely recognized for their clinical success, zirconia implants have emerged as a metal-free alternative. This study aimed to evaluate the influence of zirconia implant macrogeometry and bone density on primary implant stability. Two types of zirconia implants were tested-the Neodent Zi Ceramic Implant and the Straumann PURE Ceramic Implant, that were placed into polyurethane foam blocks mimicking different bone densities (10 PCF, 15 PCF, 20 PCF, 30 PCF, and 40 PCF).

View Article and Find Full Text PDF
Article Synopsis
  • This study examined how different implant surface characteristics affect bone integration and growth in a minipig model with a specific type of dental defect.
  • A standardized grafting method using deproteinized bovine bone was utilized, comparing three types of implants over 2 and 8 weeks.
  • Results showed that while the amount of new bone formation wasn't affected by implant type, moderately rough surfaces had better integration and bone apposition compared to a new gradient anodized implant.
View Article and Find Full Text PDF

Clinical indications for the Ti-Zr alloy (Roxolid) mini-implants (MDIs) in subjects with narrow ridges are still under review. The aim was to analyze peri-implant and posterior edentulous area strains dependent on the MDI number, splinting status, loading force, and loading position. Six models were digitally designed and printed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!