Objectives: To investigate the differences of open reduction and internal fixation (ORIF) of complex AO Type C distal radius fractures between two different models of a single implant type.
Methods: A total of 136 patients who received either a 2.4 mm (n = 61) or 3.5 mm (n = 75) distal radius locking compression plate (LCP DR) using a volar approach were followed over two years. The main outcome measurements included motion, grip strength, pain, and the scores of Gartland and Werley, the Short-Form 36 (SF-36) and the Disabilities of the Arm, Shoulder, and Hand (DASH). Differences between the treatment groups were evaluated using regression analysis and the likelihood ratio test with significance based on the Bonferroni corrected p-value of < 0.003.
Results: The groups were similar with respect to baseline and injury characteristics as well as general surgical details. The risk of experiencing a complication after ORIF with a LCP DR 2.4 mm was 18% (n = 11) compared with 11% (n = 8) after receiving a LCP DR 3.5 mm (p = 0.45). Wrist function was also similar between the cohorts based on the mean ranges of movement (all p > 0.052) and grip strength measurements relative to the contralateral healthy side (p = 0.583). In addition, DASH and SF-36 component scores as well as pain were not significantly different between the treatment groups throughout the two-year period (all p ≥ 0.005). No patient from either treatment group had a step-off > 2 mm.
Conclusions: Differences in plate design do not influence the overall final outcome of fracture fixation using LCP.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3626195 | PMC |
http://dx.doi.org/10.1302/2046-3758.16.2000008 | DOI Listing |
Osteoporos Int
January 2025
Department of Orthopaedic Surgery, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-8510, Japan.
Unlabelled: Metaphyseal comminution in distal radius fracture (DRF) cases might indicate severe osteoporosis. The patients with DRFs and metaphyseal comminution showed 5.2-fold increased secondary fractures compared with those receiving combination osteoporosis therapy.
View Article and Find Full Text PDFTrauma Case Rep
February 2025
Department of Orthopaedics and Spine Surgery, Ganga Medical Centre & Hospitals Pvt Ltd, Coimbatore, Tamil Nadu, India.
Case: A 52-year-old male fell from his bike and sustained fractures of the right proximal humerus and the left distal radius, both of which were fixed in a single sitting a day after the injury. On postoperative day four, the patient developed features suggestive of acute pulmonary embolism.
Conclusion: Reports of acute pulmonary embolism developing after surgical fixation of bilateral upper extremity fractures are rare.
Shoulder Elbow
January 2025
Department of Shoulder & Elbow, Orthopedic Institute, Sioux Falls, SD, USA.
Background: Distal biceps tendon rupture is an injury that causes a significant reduction in strength and endurance. Combined cortical button and interference screw fixation has been utilized via single-incision technique. There are limited data describing this technique utilizing a double-incision approach.
View Article and Find Full Text PDFBone Rep
March 2025
Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, United States of America.
High resolution peripheral quantitative computed tomography (HRpQCT) offers detailed bone geometry and microarchitecture assessment, including cortical porosity, but assessing chronic kidney disease (CKD) bone images remains challenging. This proof-of-concept study merges deep learning and machine learning to 1) improve automatic segmentation, particularly in cases with severe cortical porosity and trabeculated endosteal surfaces, and 2) maximize image information using machine learning feature extraction to classify CKD-related skeletal abnormalities, surpassing conventional DXA and CT measures. We included 30 individuals (20 non-CKD, 10 stage 3 to 5D CKD) who underwent HRpQCT of the distal and diaphyseal radius and tibia and contributed data to develop and validate four different AI models for each anatomical site.
View Article and Find Full Text PDFAm J Case Rep
January 2025
Department of Orthopaedics, Juntendo University Faculty of Medicine, Tokyo, Japan.
BACKGROUND Extensor pollicis longus (EPL) tendon rupture is a potential complication following distal radius fracture, typically occurring several weeks after injury. Herein, we present a rare case of acute extensor pollicis longus tendon rupture associated with a distal radius fracture. CASE REPORT A 35-year-old woman visited our hospital with a distal radius fracture.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!