The purpose of this study was to optimize scan parameters for evaluation of carotid plaque characteristics by k-space trajectory (radial scan method), using a custom-made carotid plaque phantom. The phantom was composed of simulated sternocleidomastoid muscle and four types of carotid plaque. The effect of chemical shift artifact was compared using T1 weighted images (T1WI) of the phantom obtained with and without fat suppression, and using two types of k-space trajectory (the radial scan method and the Cartesian method). The ratio of signal intensity of simulated sternocleidomastoid muscle to the signal intensity of hematoma, blood (including heparin), lard, and mayonnaise was compared among various repetition times (TR) using T1WI and T2 weighted imaging (T2WI). In terms of chemical shift artifacts, image quality was improved using fat suppression for both the radial scan and Cartesian methods. In terms of signal ratio, the highest values were obtained for the radial scan method with TR of 500 ms for T1WI, and TR of 3000 ms for T2WI. For evaluation of carotid plaque characteristics using the radial scan method, chemical shift artifacts were reduced with fat suppression. Signal ratio was improved by optimizing the TR settings for T1WI and T2WI. These results suggest the potential for using magnetic resonance imaging for detailed evaluation of carotid plaque.

Download full-text PDF

Source
http://dx.doi.org/10.6009/jjrt.2013_jsrt_69.4.407DOI Listing

Publication Analysis

Top Keywords

radial scan
24
carotid plaque
24
scan method
20
evaluation carotid
16
k-space trajectory
12
trajectory radial
12
chemical shift
12
fat suppression
12
scan parameters
8
plaque characteristics
8

Similar Publications

: Diffuse myocardial fibrosis and altered deformation are relevant prognostic factors in aortic stenosis (AS) patients. The aim of this exploratory study was to investigate the relationship between myocardial strain, and myocardial extracellular volume (ECV) in patients with severe AS with a photon-counting detector (PCD)-CT. : We retrospectively included 77 patients with severe AS undergoing PCD-CT imaging for transcatheter aortic valve replacement (TAVR) planning between January 2022 and May 2024 with a protocol including a non-contrast cardiac scan, an ECG-gated helical coronary CT angiography (CCTA), and a cardiac late enhancement scan.

View Article and Find Full Text PDF

Persistent primitive olfactory arteries (PPOAs) are a rare variant of the anterior cerebral artery (ACA). Cerebral aneurysms may arise in the PPOA; most are saccular and on the unilateral PPOA. We report a 66-year-old male with bilateral PPOAs and a fusiform aneurysm on the left side detected at a health check-up.

View Article and Find Full Text PDF

Ultra-high-resolution brain MRI at 0.55T: bSTAR and its application to magnetization transfer ratio imaging.

Z Med Phys

January 2025

Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland; Department of Radiology, Division of Radiological Physics, University Hospital Basel, Basel, Switzerland.

Purpose: This study aims to evaluate the feasibility of structural sub-millimeter isotropic brain MRI at 0.55 T using a 3D half-radial dual-echo balanced steady-state free precession sequence, termed bSTAR and to assess its potential for high-resolution magnetization transfer imaging.

Methods: Phantom and in-vivo imaging of three healthy volunteers was performed on a low-field 0.

View Article and Find Full Text PDF

This study presents a comprehensive finite element model for the human wrist, constructed from a CT scan of a 68-year-old male (type I wrist). This model intricately captures the bone and soft tissue geometries to study the biomechanics of wrist axial loading through tendon-driven simulations and grasping biomechanics using metacarpal loads. Validation is carried out by assessing the radial and ulnar axial loading distribution, radiocarpal articulation contact patterns, and other standard finite element metrics.

View Article and Find Full Text PDF

Harmonizing multisite neonatal diffusion-weighted brain MRI data for developmental neuroscience.

Dev Cogn Neurosci

January 2025

Centre for Reproductive Health, Institute for Regeneration and Repair, University of Edinburgh, UK; Centre for Clinical Brain Sciences, University of Edinburgh, UK.

Large diffusion-weighted brain MRI (dMRI) studies in neonates are crucial for developmental neuroscience. Our aim was to investigate the utility of ComBat, an empirical Bayes tool for multisite harmonization, in removing site effects from white matter (WM) dMRI measures in healthy infants born at 37 gestational weeks+ 0 days-42 weeks+ 6 days from the Theirworld Edinburgh Birth Cohort (n = 86) and Developing Human Connectome Project (n = 287). Skeletonized fractional anisotropy (FA), mean, axial and radial diffusivity (MD, AD, RD) maps were harmonized.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!