Validation of noninvasive MOEMS-assisted measurement system based on CCD sensor for radial pulse analysis.

Sensors (Basel)

Institute for Hi-Tech Development, Faculty of Mechanical Engineering and Mechatronics, Kaunas University of Technology, Studentu 65-209, Kaunas LT-51369, Lithuania.

Published: April 2013

Examination of wrist radial pulse is a noninvasive diagnostic method, which occupies a very important position in Traditional Chinese Medicine. It is based on manual palpation and therefore relies largely on the practitioner's subjective technical skills and judgment. Consequently, it lacks reliability and consistency, which limits practical applications in clinical medicine. Thus, quantifiable characterization of the wrist pulse diagnosis method is a prerequisite for its further development and widespread use. This paper reports application of a noninvasive CCD sensor-based hybrid measurement system for radial pulse signal analysis. First, artery wall deformations caused by the blood flow are calibrated with a laser triangulation displacement sensor, following by the measurement of the deformations with projection moiré method. Different input pressures and fluids of various viscosities are used in the assembled artificial blood flow system in order to test the performance of laser triangulation technique with detection sensitivity enhancement through microfabricated retroreflective optical element placed on a synthetic vascular graft. Subsequently, the applicability of double-exposure whole-field projection moiré technique for registration of blood flow pulses is considered: a computational model and representative example are provided, followed by in vitro experiment performed on a vascular graft with artificial skin atop, which validates the suitability of the technique for characterization of skin surface deformations caused by the radial pulsation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3673142PMC
http://dx.doi.org/10.3390/s130405368DOI Listing

Publication Analysis

Top Keywords

radial pulse
12
blood flow
12
measurement system
8
deformations caused
8
laser triangulation
8
projection moiré
8
vascular graft
8
validation noninvasive
4
noninvasive moems-assisted
4
moems-assisted measurement
4

Similar Publications

Objectives: To develop and validate a simplified Bleeding Audit Triage Trauma (sBATT) score for use by lay persons, or in areas and environments where physiological monitoring equipment may be unavailable or inappropriate.

Design: The sBATT was derived from the original BATT, which included prehospital systolic blood pressure (SBP), heart rate, respiratory rate, Glasgow Coma Scale (GCS), age and trauma mechanism. Variables suitable for lay interpretation without monitoring equipment were included (age, level of consciousness, absence of radial pulse, tachycardia and trapped status).

View Article and Find Full Text PDF

Femoral or Radial Secondary Access in TAVR: A Subanalysis From the Multicenter PULSE Registry.

JACC Cardiovasc Interv

December 2024

Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; Center for Population Health Innovation, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Lübeck/Kiel, Lübeck, Germany; BG University Hospital Bergmannsheil, Bochum, Germany.

Background: Transradial secondary access (TR-SA) may serve as an alternative to the traditional femoral secondary access (TF-SA) for pigtail placement in transcatheter aortic valve replacement (TAVR).

Objectives: The aim of this study was to assess the incidence of secondary access-related vascular complications after TR-SA or TF-SA in TAVR.

Methods: The PULSE (Plug or sUture based vascuLar cloSurE after TAVR) registry retrospectively evaluated data of 10,120 patients who underwent transfemoral TAVR at 10 heart centers from 2016 to 2021.

View Article and Find Full Text PDF

Objectives: The enormous burden that cardiovascular diseases put on individuals and societies warrants reliable biomarkers of disease risk to optimize disease prevention. We studied longitudinal movement (LMov) in arterial walls using ultrasound of the common carotid artery (CCA). We believe that LMov could be a sensitive biomarker of cardiovascular health and in this study, we evaluate the intra-observer repeatability and inter-observer precision of our method.

View Article and Find Full Text PDF

Objective: Targeted transcutaneous electrical nerve stimulation (tTENS) is a non-invasive neural stimulation technique that involves activating sensory nerve fibers to elicit tactile sensations in a distal, or referred, location. Though tTENS is a promising approach for delivering haptic feedback in virtual reality or for use by those with somatosensory deficits, it was not known how the perception of tTENS might be influenced by changing wrist position during sensorimotor tasks.

Approach: We worked with 12 able-bodied individuals and delivered tTENS by placing electrodes on the wrist, thus targeting the ulnar, median, and radial nerves, and eliciting tactile sensations in the hand.

View Article and Find Full Text PDF

Background: Distal radial access (DRA) through the anatomical snuff-box is a novel technique for coronary procedures. Emerging evidence suggests that DRA is associated with a lower risk of certain complications compared to proximal radial access (PRA).

Methods: A systematic review was conducted to compare clinical and procedural outcomes between both access sites for coronary angiography and percutaneous coronary intervention.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!