Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/CIRCULATIONAHA.112.127027 | DOI Listing |
J Invasive Cardiol
January 2025
Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, China; State Key Laboratory of Cardiovascular Diseases, Zhongshan Hospital, Fudan University; NHC Key Laboratory of Ischemic Heart Diseases; Key Laboratory of Viral Heart Diseases, Chinese Academy of Medical Sciences; National Clinical Research Center for Interventional Medicine, Shanghai, China.
Objectives: The ValveClamp system (Hanyu Medical Technology) is a novel transcatheter edge-to-edge repair (TEER) system designed for ease of operation; however, there is a lack of data on its application in secondary mitral regurgitation (SMR). The authors report the mid-term outcomes of TEER using the ValveClamp system in SMR.
Methods: The study prospectively analyzed consecutive severe SMR patients who underwent transapical ValveClamp implantation at 10 Chinese centers.
J Clin Med
December 2024
Herzzentrum Dresden, Department of Internal Medicine and Cardiology, Technische Universität Dresden, Fetscherstr. 76, 01307 Dresden, Germany.
Patients with end-stage kidney disease (ESRD) represent a high-risk population in terms of both development of and death by cardiovascular diseases. Outcome data of ESRD patients with severe aortic valve stenosis (AS) treated by transcatheter aortic valve implantation (AVI) are scarce. We aim to compare the outcome of ESRD patients undergoing transfemoral (TF) or transapical (TA) AVI.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
December 2024
Department of Cardiac Surgery, San Raffaele University Hospital, Milano, Italy.
Purpose: To report the outcomes of the early feasibility study of transapical transcatheter mitral valve replacement (TMVR) with the SATURN System (InnovHeart, Milano, Italy) to treat patients with severe functional mitral regurgitation.
Description: Five high surgical risk patients underwent transapical transcatheter mitral valve replacement with the SATURN System at a single center. One-year follow-up is complete for all patients.
Front Vet Sci
December 2024
Department of Clinical Sciences and James L. Voss Veterinary Teaching Hospital, College of Veterinary Medicine and Biomedical Sciences, Colorado State University, Fort Collins, CO, United States.
Objective: To determine procedural feasibility, safety, and short-term efficacy in dogs with severe degenerative mitral regurgitation (MR) undergoing transcatheter edge-to-edge repair (TEER) with a canine-specific device.
Design: Prospective, single-arm (uncontrolled), single-institution clinical feasibility study.
Animals: Fifty client-owned dogs with severe degenerative MR operated over a 28-month period.