Microwave ablation is a technique used in treating hepatocellular carcinoma, especially in cases where surgical removal is impossible. In the present study we are investigating the effects of design characteristics of a coaxial slot antenna (single- versus double-slot, slot-to-tip distance and slot size) on the ablation zone characteristics (dimensions and shape). The specific absorption rate field and the temperature rises are calculated for a variety of application times and powers. A plateau in the ablation zone dimensions in healthy and cirrhotic liver models is predicted, but not in malignant ones. It is found that the value of the perfusion rate (which is different for each clinical case) is of crucial importance in order to correctly estimate the ablation zone. An underestimation of dimensions is expected, if higher perfusion rates are used (i.e., values for healthy tissue rather than malignant). In contrast, an exact determination of the values of relative permittivity and conductivity is less significant for predicting the ablation zone.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/0031-9155/58/10/3191 | DOI Listing |
Sensors (Basel)
January 2025
Department of Mechanical Engineering, Politecnico di Milano, Via Giuseppe La Masa 1, 20156 Milan, Italy.
Radiofrequency ablation (RFA) is a minimally invasive procedure that utilizes localized heat to treat tumors by inducing localized tissue thermal damage. The present study aimed to evaluate the temperature evolution and spatial distribution, ablation size, and reproducibility of ablation zones in ex vivo liver, kidney, and lung using a commercial device, i.e.
View Article and Find Full Text PDFCardiovasc Intervent Radiol
January 2025
Interventional Radiology, The Royal Marsden, 203 Fulham Road, London, SW36JJ, UK.
Purpose: Contrast-enhanced CT (CECT) may be performed immediately following microwave liver ablation for assessment of ablative margins. However, practices and protocols vary among institutions. Here, we compare a standardized bolus-tracked biphasic CECT protocol and compare this with a single venous phase fixed delay protocol for ablation zone (AZ) assessment.
View Article and Find Full Text PDFCardiovasc Intervent Radiol
January 2025
Department of Radiology, Universidade Federal de São Paulo (UNIFESP), Rua Dr. Ovidio Pires de Campos, 75, Cerqueira César, São Paulo, SP, 05403-010, Brazil.
Purpose: To evaluate the feasibility, safety, and short-term (3-month) results of transperineal prostate thermal ablation (TPTA) as a minimally invasive outpatient treatment for benign prostatic hyperplasia (BPH).
Materials And Methods: A prospective nonrandomized study of 25 patients with lower urinary tract symptoms secondary to BPH seeking care at 2 interventional radiology centers between March and July 2024. TPTA was performed using a 17G radiofrequency needle with a 10-mm active tip under unconscious sedation combined with bilateral perineal and periprostatic nerve blocks.
Nat Commun
January 2025
Department of Cardiology, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.
Catheter-based pulmonary artery denervation (PADN) has achieved promising outcomes to treat pulmonary hypertension (PH). We herein present stereotactic body radiotherapy (SBRT) as a novel noninvasive approach for PADN. A single fraction of 15 Gy, 20 Gy or 25 Gy was delivered for PADN in a thromboxane A2 (TxA2) - induced acute PH swine model.
View Article and Find Full Text PDFBiomed Eng Lett
January 2025
Power Electronics Research Centre, School of Engineering, University of Galway, Galway, Ireland.
Purpose: Pulsed electrical field (PEF) ablation is an energy-based technique used to treat a range of cancers by irreversible electroporation (IRE). Our objective was to use computational and plant-based models to characterize the electric field distribution and ablation zones induced with a commercial 8-needle array-based applicator intended for treatment of skin cancer when high-frequency IRE (H-FIRE) pulses are applied. Electric field characterisation of this device was not previously assessed.