Stent effects on duplex velocity estimates.

J Surg Res

Department of Vascular and Endovascular Surgery, Wake Forest University School of Medicine, Winston-Salem, North Carolina 27157, USA.

Published: July 2013

Background: Doppler-derived velocity criteria used to define the presence and severity of in-stent restenosis after percutaneous angioplasty and endoluminal stenting have been called into question. This study uses an in vitro flow model to examine Doppler-derived velocities after placement of balloon-expandable and self-expanding endoluminal stents (BES and SES).

Methods: An in vitro vascular circuit model consisting of a pulsatile pump, tubing, and a conduit was created. The pump was programmed to replicate the Doppler spectral waveform pattern of the renal and carotid arteries. Peak systolic velocity (PSV) and end diastolic velocity (EDV) were estimated at five distinct conduit locations. Three replicate velocity measurements were made at each location. After initial velocity estimates, a BES or an SES was deployed within the conduit.

Results: Mean ± standard error PSV was 95.8 ± 2.6 cm/s, 97.0 ± 2.7 cm/s, and 101.4 ± 2.7 cm/s for unstented, BES and SES, respectively. PSV estimates were increased between unstented and stented conduits when SESs were present. The increase in mean systolic velocity of 6.4% observed with SES was statistically significant (P < 0.05). EDV values did not differ significantly across conditions. Mean ± standard error EDV was 36.2 ± 1.0 cm/s, 37.3 ± 1.1 cm/s, and 37.2 ± 1.1 cm/s for unstented, BES, and SES, respectively.

Conclusion: The presence of an SES was associated with a less than 7% change in estimated PSV. These results suggest that Doppler velocity estimates for renal and carotid arteries are not materially affected by either BES or SES.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jss.2012.03.004DOI Listing

Publication Analysis

Top Keywords

bes ses
16
velocity estimates
12
velocity
8
renal carotid
8
carotid arteries
8
systolic velocity
8
standard error
8
cm/s unstented
8
unstented bes
8
ses
6

Similar Publications

Lithium solid-state batteries offer improved safety and energy density. However, the limited stability of solid electrolytes (SEs), as well as irreversible structural and chemical changes in the cathode active material, can result in inferior electrochemical performance, particularly during high-voltage cycling (>4.3 V vs Li/Li).

View Article and Find Full Text PDF

Evaluation of balloon and self-expandable stents for common femoral artery stenosis.

J Vasc Surg

February 2025

Cardio-vascular and Thoracic Surgery Department, Dijon University Hospital, Dijon, France; PEC 2 EA 7460, University of Burgundy, Dijon, France.

Background: Endovascular treatment of the common femoral artery (CFA) and its bifurcation is currently recommended for patients with hostile groin (prior femoral bifurcation open surgery, history of radiotherapy) or severe comorbidities (advanced age, frailty, obesity). Preliminary results have shown favorable outcomes. Among the different endovascular techniques (atherectomy, intravascular lithotripsy, plain balloon angioplasty, drug-coated balloon angioplasty, stenting), stents are mainly used but the best type of stent to use is still debated.

View Article and Find Full Text PDF
Article Synopsis
  • Diabetes mellitus increases the risk of target lesion failure (TLF) after coronary interventions, prompting a study on 5-year outcomes of biodegradable polymer stents in diabetic patients.
  • The SORT OUT VII trial compared the effectiveness of two different stents (O-SES and N-BES) in over 2,500 patients, focusing on TLF and other heart-related issues over five years.
  • Results showed that diabetic patients had higher TLF and patient-related complications compared to non-diabetics, but no significant differences in TLF rates between the two stent types among diabetic patients.
View Article and Find Full Text PDF

Iliac artery angioplasty with stenting is an effective alternative treatment modality for aortoiliac occlusive diseases. Few randomized controlled trials have compared the efficacy and safety between self-expandable stent (SES) and balloon-expandable stent (BES) in atherosclerotic iliac artery disease. In this randomized, multicenter study, patients with common or external iliac artery occlusive disease were randomly assigned in a 1:1 ratio to either BES or SES.

View Article and Find Full Text PDF

Incidence and Risk Factors of Iliac Artery Rupture during Aortoiliac Stenting.

Vasc Specialist Int

February 2024

Department of Surgery, Kyung Hee University Hospital at Gangdong, Kyung Hee University School of Medicine, Seoul, Korea.

Purpose: Aortoiliac occlusive disease (AIOD) is widely prevalent and leads to severe claudication or chronic limb-threatening ischemia. Stent placement for AIOD demonstrated excellent outcomes in terms of long-term patency. However, iliac artery rupture is the most fearful complication during the aortoiliac stenting (AIS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!