Objective: To propose a method to assess and report the amount of neurovascular tissue present in radical prostatectomy (RP) specimens.

Patients And Methods: The data of 133 consecutive patients who underwent robot-assisted RP by a single surgeon (V.R.P.) were prospectively collected. Degree of nerve sparing (NS) was graded intraoperatively by the surgeon independently at either side as complete, partial or none. A pathologist who was 'blinded' to the surgeon's classification measured the following parameters at the posterolateral aspect of the apex, base and mid prostate at either side of the RP specimen: length, width and area of neural tissue, number of nerves per high-power field and number of total slides containing neural tissue. Measurements were correlated to the surgeon's intraoperative perception.

Results: All measurements correlated significantly with surgeon's intent of NS at all locations (P = 0.001). Among them, the cross-sectional area had the highest correlation coefficient (-0.550 at apex, -0.604 at mid prostate and -0.606 at the base).

Conclusions: The cross-sectional area of nerve tissue showed the highest correlation with surgeon's intent of NS at all locations. Having a standardised method of assessing and reporting residual nerve tissue allows the surgeon to objectively evaluate the quality of nerve preservation and to compare the progress of his NS technique over time.

Download full-text PDF

Source
http://dx.doi.org/10.1111/bju.12038DOI Listing

Publication Analysis

Top Keywords

method assess
8
assess report
8
neurovascular tissue
8
tissue radical
8
radical prostatectomy
8
mid prostate
8
neural tissue
8
measurements correlated
8
correlated surgeon's
8
surgeon's intent
8

Similar Publications

Introduction: Unmet health care needs are seen as a key indicator of equity in access to health care. With younger people, they can lead to poorer health outcomes in adulthood, and in older people they can be associated with an increased risk of mortality. The presence of a disability is considered a risk factor for unmet needs.

View Article and Find Full Text PDF

A scoping review of interventions to optimize medication adherence in hypertension comorbidity.

Res Social Adm Pharm

January 2025

Department of Pharmacy Practice and Clinical Pharmacy, School of Pharmacy, College of Health Sciences, University of Ghana, P. O. Box LG 43, Legon, Ghana. Electronic address:

Background: Patients with hypertension and other comorbidities have difficulties adhering to their medications which have negative impacts on clinical outcomes. Although some studies have identified strategies to improve medication adherence, a thorough analysis of these interventions will provide synthesized evidence for clinical decision-making and improved health outcomes for patients with hypertension comorbidities.

Aim: To conduct a scoping review on interventions that have been utilised to improve medication adherence in patients with hypertension and other co-morbid conditions.

View Article and Find Full Text PDF

A collaborative interdisciplinary approach for trigger finger management.

J Hand Ther

January 2025

Venture Rehabilitation Sciences Group, Saskatoon, SK, Canada; School of Rehabilitation Science, University of Saskatchewan, Saskatoon, SK, Canada. Electronic address:

Background: Stenosing tenosynovitis, or trigger finger, is a common cause of hand disability. This study outlines a trigger finger management protocol that redirects referrals for surgical consultations to conservative management first.

Purpose: The primary outcome variable was the protocol endpoint based on the resolution of trigger finger symptoms (i.

View Article and Find Full Text PDF

Evaluation of a Deep Learning Denoising Algorithm for Dose Reduction in Whole-Body Photon-Counting CT Imaging: A Cadaveric Study.

Acad Radiol

January 2025

Department of Radiology, University Hospital Tuebingen, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany (R.D., J.M.B., B.S., J.M., S.G., P.K., S.W., J.H., K.N., S.A., A.B.).

Rationale And Objectives: Photon Counting CT (PCCT) offers advanced imaging capabilities with potential for substantial radiation dose reduction; however, achieving this without compromising image quality remains a challenge due to increased noise at lower doses. This study aims to evaluate the effectiveness of a deep learning (DL)-based denoising algorithm in maintaining diagnostic image quality in whole-body PCCT imaging at reduced radiation levels, using real intraindividual cadaveric scans.

Materials And Methods: Twenty-four cadaveric human bodies underwent whole-body CT scans on a PCCT scanner (NAEOTOM Alpha, Siemens Healthineers) at four different dose levels (100%, 50%, 25%, and 10% mAs).

View Article and Find Full Text PDF

Rationale And Objectives: Alzheimer's disease (AD) is the most common pathogenesis of dementia, and mild cognitive impairment (MCI) is considered as the intermediate stage from normal elderly to AD. Early detection of MCI is an essential step for the timely intervention of AD to slow the progression of this disease. Different form previous studies in the whole-brain spontaneous activities, this research aimed to explore the low-frequency amplitude spectrum activities of patients with MCI within the default mode network (DMN), which has been involved in the process of maintaining normal cognitive function.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!