Detection of photons from electromagnetic radiation can be considered as the appearance of random events on the time axis. When an attenuator is placed in front of the detector, which attenuates the intensity by a factor of α, the statistical properties of the detected photons are altered. We show that simple relations exist between the statistical functions of the photons detected from the attenuated field and the same functions for the photons that would be detected from the unattenuated field. We also derive several recurrence relations for the statistical functions involving their dependence on the parameter α. For photon detection from resonance fluorescence, the parameter α appears naturally as the probability that an emitted photon is detected. In this case, there is no attenuator, but the parameter α appears in the same way. We show that the probability for the emission (α=1) of n photons in a given time interval can easily be computed, and with the general theory we can then obtain the result for the detection of n photons (α<1).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/JOSAA.30.000749 | DOI Listing |
Light Sci Appl
January 2025
National Research Center for High-Efficiency Grinding, College of Mechanical and Vehicle Engineering, Hunan University, 410082, Changsha, China.
Accurately and swiftly characterizing the state of polarization (SoP) of complex structured light is crucial in the realms of classical and quantum optics. Conventional strategies for detecting SoP, which typically involves a sequence of cascaded optical elements, are bulky, complex, and run counter to miniaturization and integration. While metasurface-enabled polarimetry has emerged to overcome these limitations, its functionality predominantly remains confined to identifying SoP within the standard Poincaré sphere framework.
View Article and Find Full Text PDFRadiol Clin North Am
March 2025
Department of Medicine, UT Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, TX 75390-8558, USA; Department of Pediatrics, UT Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, TX 75390-8558, USA. Electronic address:
Pulmonary vascular diseases, particularly when accompanied by pulmonary hypertension, are complex disorders often requiring multimodal imaging for diagnosis and monitoring. Echocardiography is the primary screening tool for pulmonary hypertension, while cardiac MR imaging (CMR) is used for more detailed characterization and risk stratification in right ventricular failure. Chest computed tomography (CT) is used to detect vascular anomalies and parenchymal lung diseases.
View Article and Find Full Text PDFNucl Med Biol
January 2025
Central Research Laboratory, Hamamatsu Photonics K.K., Hamana, Hamamatsu, Shizuoka 434-8601, Japan.
Background: The ovary is an important female organ not only for pregnancy but also for the regulation of life activities via hormone release. Ovarian function is measured by blood hormone levels, but the hormone level reflects only the ovarian reserve and no other essential ovarian functions, such as nurturing and expelling follicles. Ovarian fibrosis is related to essential ovarian function; however, the existing methods for evaluating fibrosis are invasive.
View Article and Find Full Text PDFPolymers (Basel)
January 2025
Shandong Key Laboratory of Healthy Food Resources Exploration and Creation, School of Food Science and Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China.
As a veterinary drug, sulfamethazine is frequently used to control animal diseases. In this study, a novel molecularly imprinted photonic crystal sensor for the fast visual detection of sulfamethazine in milk and chicken has been developed. Under optimum preparation conditions, a molecularly imprinted, photonic crystal with an anti-opal structure and a clear bright color was prepared and characterized.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Institute of Electronics, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan.
Single-Photon Avalanche Photodiodes (SPADs) are increasingly utilized in high-temperature-operated, high-performance Light Detection and Ranging (LiDAR) systems as well as in ultra-low-temperature-operated quantum science applications due to their high photon sensitivity and timing resolution. Consequently, the jitter value of SPADs at different temperatures plays a crucial role in LiDAR systems and Quantum Key Distribution (QKD) applications. However, limited studies have been conducted on this topic.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!