Objective: To evaluate the effects of the magnetic particle antibody immunoassay (MPAIA), dipstick dye immunoassay (DDIA) and indirect hemagglutination assay (IHA), on detecting advanced schistosomiasis.

Methods: The sera of 224 cases of advanced schistosomiasis were detected by MPAIA, DDIA, and IHA, and the positive rates were compared.

Results: The positive rates of MPAIA, DDIA and IHA, were 67.14%, 14.29% and 16.52%, respectively,the positive coincidence rate of MPAIA is higher than the one of IHA and DDIA.

Conclusion: The value of MPAIA is higher than that of DDIA or IHA in screening advanced schistosomiasis.