A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Application of the water subtraction algorithm in determining the degree of conversion of self-etching adhesives. | LitMetric

Purpose: This study evaluated the effect of residual water included within the FT-IR spectra on the calculation of the degree of conversion (DC) of a self-etching adhesive (SEA).

Materials And Methods: FT-IR spectra of a SEA (Adper Prompt SE, 3M ESPE) were obtained for different amounts of dentin powder, agitation times, and light-curing times. The measured DC (mDC) obtained from the IR spectra was compared to the apparent DC (aDC) from the adjusted IR spectra using the water subtraction algorithm (WSA), by which the water absorption band was subtracted from the obtained IR spectrum.

Results: When the SEA was mixed with 10 mg of dentin powder, the aDC was significantly higher than the mDC immediately after light curing (paired t-test, p < 0.001). With the increase in the amount of dentin powder, the mDC immediately after curing and the difference between the mDC and the aDC gradually increased. The amount of dentin powder, light-curing time, square of light-curing time, and time until measurement were the variables that significantly affected the aDC (linear mixed model, p < 0.05). However, the agitation time did not affect the aDC or the difference between the mDC and the aDC, except at 20 s.

Conclusion: When the DC of SEA itself is measured with FT-IR, the mDC needs to be adjusted with the water subtraction algorithm. Clinically, SEA needs to be applied under conditions of prolonged contact with the dentin substrate and vigorous and prolonged drying.

Download full-text PDF

Source
http://dx.doi.org/10.3290/j.jad.a29589DOI Listing

Publication Analysis

Top Keywords

dentin powder
16
water subtraction
12
subtraction algorithm
12
degree conversion
8
conversion self-etching
8
ft-ir spectra
8
amount dentin
8
difference mdc
8
mdc adc
8
light-curing time
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!