Within-day test-retest reliability of the Timed Up & Go test in patients with advanced chronic organ failure.

Arch Phys Med Rehabil

Program Development Center, Center of Expertise for Chronic Organ Failure (CIRO+), Horn, The Netherlands; Centro de Pesquisa em Ciências da Saúde, Centro de Ciências Biológicas e da Saúde, Universidade Norte do Paraná (UNOPAR), Londrina, Paraná, Brazil; Laboratório de Pesquisa em Fisioterapia Pulmonar, Departamento de Fisioterapia, Universidade Estadual de Londrina (UEL), Londrina, Paraná, Brazil. Electronic address:

Published: November 2013

Objective: To investigate the within-day test-retest reliability of the Timed Up & Go (TUG) test in patients with advanced chronic obstructive pulmonary disease (COPD), chronic heart failure (CHF), and chronic renal failure (CRF).

Design: Cross-sectional.

Setting: Patients' home environment.

Participants: Subjects (N=235, 64% men; median age, 70y [interquartile range, 61-77y]; median body mass index, 25.6kg/m(2) [interquartile range, 22.8-29.4kg/m(2)]) with advanced COPD (n=95), CHF (n=68), or CRF (n=72).

Interventions: Not applicable.

Main Outcome Measure: Time to complete the TUG test. Three trials were performed on the same day and by the same assessors. The intraclass correlation coefficient (ICC), kappa coefficient, standard error of measurement, and absolute and relative minimal detectable change (MDC) values were calculated.

Results: Good agreement was observed, in general, for both the total sample and subgroups (COPD, CHF, CRF), with ICC values ranging from .85 to .98, and kappa coefficients from .49 to 1.00. However, statistical improvement occurred in the total sample from the first to the second trial with large limits of agreement (mean difference, -.97s; 95% confidence interval, 3.00 to -4.94s; P<.01). The third trial added little or no information to the first 2 trials. For the total sample, a standard error of measurement value of approximately 1.6 seconds, an absolute value of MDC at the 95% confidence level (MDC95%) of approximately 4.5 seconds, and a relative value of MDC at the 95% confidence level (MDC95%%) of approximately 35% were found between the first 2 trials, with similar values found for the subgroups.

Conclusions: The TUG test is reliable in patients with advanced COPD, CHF, or CRF after 2 trials. Values of standard error of measurement and MDC may be used in daily clinical practice with these populations to define what is expected and what represents true change in repeated measures.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apmr.2013.03.024DOI Listing

Publication Analysis

Top Keywords

within-day test-retest
8
test-retest reliability
8
reliability timed
8
test patients
8
patients advanced
8
advanced chronic
8
tug test
8
[interquartile range
8
total sample
8
timed test
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!