Objective: To facilitate further assessment of transfusion-associated lead exposure by designing a procedure to test packed red blood cells (pRBCs) prepared for transfusion.

Study Design: The relationship between pRBCs and whole blood lead concentration was investigated in 27 samples using a modified clinical assay. Lead concentrations were measured in 100 pRBC units.

Results: Our sample preparation method demonstrated a correlation between whole blood lead and pRBC lead concentrations (R(2) = 0.82). In addition, all 100 pRBC units tested had detectable lead levels. The median pRBC lead concentration was 0.8 μg/dL, with an SD of 0.8 μg/dL and a range of 0.2-4.1 μg/dL. In addition, after only a few days of storage, approximately 25% of whole blood lead was found in the supernatant plasma.

Conclusion: Transfusion of pRBCs is a source of lead exposure. Here we report the quantification of lead concentration in pRBCs. We found a >20-fold range of lead concentrations in the samples tested. Pretransfusion testing of pRBC units according to our proposed approach or donor screening of whole blood lead and selection of below-average units for transfusion to children would diminish an easily overlooked source of pediatric lead exposure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4795168PMC
http://dx.doi.org/10.1016/j.jpeds.2013.03.003DOI Listing

Publication Analysis

Top Keywords

lead exposure
16
blood lead
16
lead
14
lead concentration
12
lead concentrations
12
pediatric lead
8
100 prbc
8
prbc lead
8
prbc units
8
blood
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!