The European Centre for the Validation of Alternative Methods (ECVAM) has supported validation studies on in vitro tests for skin corrosion, resulting in the validities of four alternative tests being endorsed. The US Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM) has also evaluated the validity of these alternative methods for skin corrosion testing. In the European Union, a new Test Method on Skin Corrosion (B.40), incorporating the rat skin transcutaneous electrical resistance and human skin model assays, was included in Annex V of Directive 67/548/EEC in mid-2000. At an international level, two OECD Test Guidelines (430 and 431) on these alternative methods have been approved as of May 2002. To date, there are no validated in vitro tests for predicting the dermal irritancy of chemicals. ECVAM supported prevalidation studies on five in vitro tests for acute skin irritation during 1999-2001. These tests were based on human, pig and mouse skin. However, none of them met the criteria set for inclusion in a large-scale formal validation study. Following additional work on the test protocols and/or prediction models, it appears that several modified tests could now be ready for validation in 2003.

Download full-text PDF

Source
http://dx.doi.org/10.1177/026119290403201s113DOI Listing

Publication Analysis

Top Keywords

skin corrosion
16
alternative methods
16
vitro tests
12
alternative tests
8
skin
8
tests skin
8
validation alternative
8
ecvam supported
8
studies vitro
8
tests
7

Similar Publications

Management of plane warts is difficult; techniques like cryotherapy and cauterization are linked with a significant number of recurrences, risk of scarring, pain, and costs. To evaluate the effectiveness of TCA 30% solution in comparison with tretinoin 0.05% cream and5-flurouracil (5-FU) 5% cream in treatment of plane wart.

View Article and Find Full Text PDF

Hydrogels are flexible materials characterized by a 3D network structure, which possess high water content and adjustable physicochemical properties. They have found widespread applications in tissue engineering, electronic skin, drug delivery, flexible sensors, and photothermal therapy. However, hydrogel networks often exhibit swelling behavior in aqueous environments, which can result in structural degradation and a loss of gel performance.

View Article and Find Full Text PDF

Electrochemical Detection of Hydrogen Peroxide at High Concentrations Using Hastelloy G35 Electrode.

Langmuir

January 2025

State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun, Jilin 130022, P R China.

The detection of hydrogen peroxide (HO) at elevated concentrations while eliminating oxygen interference presents a significant challenge. Nickel-based stainless steel, such as Hastelloy G35, has shown excellent corrosion resistance. However, it has never been used in electroanalysis.

View Article and Find Full Text PDF

Wounds resulting from intradermal injection of sodium hypochlorite: a case report.

Wounds

December 2024

Dermatology Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy; Department of Medical and Surgical Sciences, Alma Mater Studiorum University of Bologna, Bologna, Italy.

Background: Caustic substances can inflict severe damage on tissues upon contact. Knowledge about skin damage caused by sodium hypochlorite is quite limited, with only a few reports available in the literature.

Case Report: A 79-year-old female with severe cognitive decline presented with multiple skin ulcerations that were covered by a blackish-greyish eschar and surrounded by a purple erythematous halo.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!