Fetal liver T2* values: defining a standardized scale.

J Magn Reson Imaging

Diagnostic Imaging, Chaim Sheba Medical Center, affiliated with the Sackler Medical School, Tel Aviv University, Tel Aviv, Israel.

Published: December 2013

Purpose: To define the normal T2* values of liver in the third trimester of pregnancy in normal fetuses.

Materials And Methods: Multi-echo gradient echo T2* sequence was applied to the fetal abdomen in the axial plane in women undergoing a fetal MRI (1.5 Tesla [T], MRI system). A region of interest, best visualizing in the liver parenchyma was used for measurements. Studies were independently read by two experienced readers to assess intra- and interobserver variability.

Results: The study cohort included 46 pregnant women undergoing fetal MRI for any indication other than liver pathology evaluation. Three scans were excluded due to fetal motion. Average maternal and gestational age were 33 ± 4 years and 31.9 ± 3 weeks, respectively. Average T2* values were found to be 19.7 ± 7.4 ms. The intra- and interobserver agreement were very good: 0.93 and 0.8-0.084, respectively.

Conclusion: T2* MRI allows noninvasive evaluation liver iron content in the third trimester fetus. Measured values at this stage of pregnancy are significantly lower compared with values cited in the literature for adults. This is of major importance in the correct diagnosis of fetal iron overload states. We propose this as the standard reference when evaluating fetal iron overload pathology.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jmri.24132DOI Listing

Publication Analysis

Top Keywords

t2* values
12
third trimester
8
women undergoing
8
undergoing fetal
8
fetal mri
8
intra- interobserver
8
fetal iron
8
iron overload
8
fetal
7
t2*
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!