We report three patients with deposition of pseudoexfoliation (PXF) material on intraocular lens years after uneventful cataract surgery. PXF was not present before the cataract surgery. The PXF material was found on the anterior surface of the intraocular lens in the first patient and on the posterior surface as well in the other two patients. All the patients had a polymethylmethacrylate intraocular lens placed in the sulcus. The fellow eyes did not have PXF. All the patients had open angle glaucoma in both eyes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3759111PMC
http://dx.doi.org/10.4103/0301-4738.109514DOI Listing

Publication Analysis

Top Keywords

intraocular lens
12
pxf material
8
cataract surgery
8
surgery pxf
8
pseudoexfoliation pseudophakos
4
pseudophakos report
4
report three
4
patients
4
three patients
4
patients deposition
4

Similar Publications

Purpose: To identify the minimally required number of distances of visual acuity (VA) measurements for the reliable estimation of the visual acuity curve (VAC) and area of the curve (AoC) in presbyopia correction.

Patients And Methods: The study was divided into a validation and a clinical phase with a total recruitment of 120 participants (120 eyes) who underwent uncomplicated pseudophakic presbyopia surgery with bilateral premium intraocular lenses (IOL) implantation. This study was conducted in the Department of Ophthalmology, University Hospital of Alexandroupolis, Alexandroupolis, Greece.

View Article and Find Full Text PDF

Introduction: Implantable collamer lens (ICL) is a posterior chamber phakic intraocular lens. It is usually indicated for high refractive error correction that cannot be treated by laser vision correction due to physical limitations.

Case Presentation: 39 years old male with a past ocular history of keratoconus underwent astigmatic keratotomy followed by crosslinking in both eyes a couple of years later due to signs of corneal ectasia progression.

View Article and Find Full Text PDF

Purpose: The research investigates the efficacy of hydroxypropyl methylcellulose (HPMC) treatment in facilitating the development of compact water droplets on the rear surface of synthetic lenses with capsule imperfections during the process of fluid-air exchange.

Method: This study examined four patients with intraocular lens (IOL) implants and posterior capsule defects who experienced the formation of dense water droplets on the posterior surface following fluid-air exchange. When this occurrence obstructs fundus visualization during surgery, it is recommended to suspend the surgical procedure.

View Article and Find Full Text PDF

Purpose: To evaluate dynamic changes in ciliary parameters and Implantable Collamer Lens V4C (ICL) (STAAR Surgical) haptic position using mydriatic and miotic agents and their effects on the central and peripheral vault.

Methods: This study involved 80 eyes from 40 consecutive patients (mean age: 28.05 years; range: 19 to 42 years) examined 3 months after ICL implantation.

View Article and Find Full Text PDF

Purpose: To evaluate the 12-month rotational stability and outcomes of V4c toric Implantable Collamer Lenses (TICLs) (STAAR Surgical) located at two different lens orientations (horizontal or oblique).

Methods: This retrospective study included a total of 403 eyes with TICL implantation, enrolled between January 2021 and December 2022, that were divided into two groups based on the minimum intended angle off the horizontal axis: horizontal with 263 eyes at an angle ±22.5 degrees or less and oblique with 140 eyes at a minimum intended angle of greater than ±22.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!