Poor screw purchase because of osteoporosis presents difficulties in ankle fracture fixation. The aim of our study was to determine if cortical thickness, unicortical versus bicortical purchase, and bone mineral density are predictors of inadvertent screw stripping and overtightening. Ten paired cadaver ankles (average donor age, 81.7 years; range, 50-97 years) were used for the study. Computed tomography scanning with phantoms of known density was used to determine the bone density along the distal fibula. A standard small-fragment, 7-hole, one-third tubular plate was applied to the lateral surface of the fibula, with 3 proximal bicortical cortical screws and 2 distal unicortical cancellous screws. A posterior plate, in which all 5 screws were cortical and achieved bicortical purchase, was subsequently applied to the same bones and positioned so that the screw holes did not overlap. A torque sensor was used to measure the torque of each screw during insertion (Ti) and then stripping (Ts). The effect of bone density, screw location, cortical thickness, and unicortical versus bicortical purchase on Ti and Ts was checked for significance (P < .05) using a general linearized latent and mixed model. We found that 9% of the screws were inadvertently stripped and 12% were overtightened. Despite 21% of the screws being stripped or being at risk for stripping, we found no significant predictors to warn of impending screw stripping. Additional work is needed to identify clinically useful predictors of screw stripping.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3597310 | PMC |
http://dx.doi.org/10.1177/2151458511401352 | DOI Listing |
J Foot Ankle Surg
January 2025
Enovis Foot & Ankle, Atlanta, GA; Georgia Institute of Technology, Atlanta, GA. Electronic address:
Orthopedic screws are widely used to achieve bone reduction, compression, and construct stability. However, the relationship between insertion torque, interfragmentary compression, and fixation strength, especially when comparing standard screws with NiTiNOL/sustained dynamic compression (SDC), has not been thoroughly investigated. This study measured insertion torque, interfragmentary compression, and fixation strength for two types of headed orthopedic devices-standard and SDC-using solid foam bone replicates and cadaver validation.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Orthopaedics, The Fourth Affiliated Hospital of Zhejiang University School of Medicine, Yiwu, China.
The purpose of this study was to present the surgical technique of Unilateral Biportal Endoscopic (UBE) decompression combined with percutaneous pedicle screws for the treatment of thoracolumbar burst fractures with secondary spinal stenosis. Thoracolumbar burst fracture is a common traumatic disease in spinal surgery. In the Arbeitsgemeinschaft für Osteosynthesefragen (AO) classification of thoracolumbar fractures, Type A fractures have the highest incidence, accounting for about 70%, with A1 and A3 types being the most common.
View Article and Find Full Text PDFJ Orthop Case Rep
November 2024
Department of Orthopaedics, Jaipur Golden Hospital, Institutional Area Sector 3 Rohini, Delhi, India.
Introduction: Proximal femoral nail antirotation - II (PFNA- II) is a common treatment for intertrochanteric fractures in the elderly. Removing PFNA is difficult in rare circumstances due to blade head stripping or breaking. In this article, we endeavored to explain an easy methodology that can be utilized to remove stripped, damaged anti-rotation blades for which few had been formulated but other procedures have failed.
View Article and Find Full Text PDFBMC Surg
October 2024
Department of orthopedics, the First Affiliated Hospital, Fujian Medical University, Fuzhou, 350004, China.
Background: Due to its deep position and complex surrounding anatomy, the scapular glenoid fracture was relatively difficult to deal with especially in cases of severe fracture displacement. Improper treatment may lead to failure of internal fixation and poor fracture reduction, severely affecting the function of the shoulder joint. Inferior scapular glenoid fracture was Ideberg type II fracture, and posterior approach was commonly used to deal with inferior scapular glenoid fracture.
View Article and Find Full Text PDFJ Orthop Trauma
February 2025
Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!