AI Article Synopsis

  • The study investigated the surface characteristics of polyetheretherketone (PEEK) and its adhesion to two types of veneering resins under different treatments.
  • Silica coatings provided the best surface wettability, while acid etching yielded the highest shear bond strength compared to other methods tested.
  • PEEK fixed dental prostheses (FDPs) demonstrated strong structural integrity with a fracture load averaging 1383 N, indicating its potential for use in high-stress dental applications.

Article Abstract

Objectives: To study the surface properties of polyetheretherketone (PEEK) and its bond strength with two veneering resins after different conditioning methods as well as fracture load of PEEK three-unit fixed dental prostheses (FDPs).

Methods: Two hundred and twenty five PEEK specimens were fabricated and divided into five groups: no treatment (A), etching with 98% sulfuric acid for 1 min (B), air-abrasion for 10 s with either 50 or 110 μm alumina (C and D, respectively), and silica coating using the Rocatec System (E). On 15 specimens of each conditioning method, contact angle and surface roughness were determined. The remaining 150 specimens of each conditioning method were divided into two groups for the veneering procedure with the composites Gradia (GC Europe) and Sinfony (3M ESPE). Shear bond strength (SBS) was measured and failure types were assessed. In addition, 15 FDPs were milled and the fracture load was tested. Data were analyzed using descriptive statistics, one-way ANOVA (Scheffé test), two sample Student's t-test, and Weibull statistics (p < 0.05).

Results: Silica-coated PEEK surfaces showed the highest wettability. The highest roughness and lowest contact angles were observed for 110 μm air-abraded and silica-coated PEEK surfaces. The highest SBS values were, however, achieved in the acid-etched group. PEEK three-unit FDPs showed a mean fracture load of 1383 N with a plastic deformation starting approximately at 1200 N.

Conclusions: Acid etching should be applied when PEEK is used as substructure material and composite veneering material is applied. In this combination, PEEK might be a suitable material for FDPs, especially in load-bearing areas.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.32932DOI Listing

Publication Analysis

Top Keywords

fracture load
12
suitable material
8
fixed dental
8
peek
8
bond strength
8
peek three-unit
8
divided groups
8
110 μm
8
specimens conditioning
8
conditioning method
8

Similar Publications

Fiber-reinforced polymer composites are subjected to harsh environmental conditions over the course of their designed lifespan. Studying the aging process of fiber-reinforced polymer composites exposed to boiling water is critical for improving their durability. This study uses a hand lay-up technique to fabricate composites from glass fiber, bamboo fiber, nanoclay, and epoxy.

View Article and Find Full Text PDF

Objective: Aim: Study the mechanism of interaction between the 'sacroiliac joint - screw' system and determine the optimal parameters of the stabilizing structure, the strength of the system connection through computer modeling, and anatomical-biomechanical experiment.

Patients And Methods: Materials and Methods: The optimal parameters of the stabilizing structure for the sacroiliac joint were calculated using software package MathCAD. To validate the results of the numerical modeling, corresponding investigations of mechanical characteristics and determination of stiffness of the studied systems were conducted by an upgraded testing stand, TIRAtest-2151.

View Article and Find Full Text PDF

Background: The aim of study was to biomechanically compare the fixation of Jones fracture using headless cannulated screw, tension band, and two Kirschner wires.

Methods: A total of 60 fourth-generation, fifth metatarsal synthetic bone models were divided into three groups according to the fixation techniques. A vertical load, oriented from plantar to dorsal and lateral to medial, was applied to the metatarsal specimen that were potted with molding material.

View Article and Find Full Text PDF

Objective: The aim of this study was to evaluate whether the locking femoral neck plate (LFNP) can be an alternative fixation method to the cannulated screws with a medial buttress plate. For this purpose, we compared biomechanically the LFNP and cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures.

Methods: A vertical fracture model was created at an 80-degree angle to the femoral neck in 28 synthetic bone models.

View Article and Find Full Text PDF

Background/purpose: Although clinical studies have suggested a link between non-axial forces and reduced longevity of cervical restorations, the underlying mechanisms require further numerical investigation. This in-silico study employed a cohesive zone model (CZM) to investigate interfacial damage in a cervical restoration subjected to different load directions.

Materials And Methods: A plane strain model of a maxillary premolar was established, with a wedge-shaped buccal cervical restoration.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!