The impact of chronic blood-brain barrier breach on intracortical electrode function.

Biomaterials

Wallace H. Coulter Department of Biomedical Engineering at Georgia Institute of Technology, Emory University School of Medicine, Atlanta, GA 30332-0535, USA.

Published: July 2013

Brain-computer interfaces (BCIs) have allowed control of prosthetic limbs in paralyzed patients. Unfortunately, the electrodes of the BCI that interface with the brain only function for a short period of time before the signal quality on these electrodes becomes substantially diminished. To truly realize the potential of BCIs, it is imperative to have electrodes that function chronically. In order to elucidate the physiological determinants of a chronically functional neural interface, we studied the role of the blood-brain barrier (BBB) in electrode function, because it is a key mediator of neuronal hemostasis. We monitored the status of the BBB and the consequences of BBB breach on electrode function using non-invasive imaging, electrophysiology, genomic, and histological analyses. Rats implanted with commercially available intracortical electrodes demonstrated an inverse correlation between electrode performance and BBB breach over a period of 16 weeks. Genomic analysis showed that chronically functional electrodes elicit an enhanced wound healing response. Conversely, in poorly functioning electrodes, chronic BBB breach led to local accumulation of neurotoxic factors and an influx of pro-inflammatory myeloid cells, which negatively affect neuronal health. These findings were further verified in a subset of electrodes with graded electrophysiological performance. In this study, we determine the mechanistic link between intracortical electrode function and failure. Our results indicate that BBB status is a critical physiological determinant of intracortical electrode function and can inform future electrode design and biochemical intervention strategies to enhance the functional longevity of BCIs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.biomaterials.2013.03.007DOI Listing

Publication Analysis

Top Keywords

electrode function
20
intracortical electrode
12
bbb breach
12
blood-brain barrier
8
chronically functional
8
electrode
7
function
7
electrodes
7
bbb
6
impact chronic
4

Similar Publications

Hydrogen-bond-driven 1D assembly of carbon nanotubes dispersed in organic solvents remains challenging owing to difficulties associated with achieving high oxidation levels and uniform dispersion. Here, we introduced a bioinspired wet-spinning method that utilizes highly oxidized single-walled carbon nanotubes dispersed in organic solvents without superacid or dispersants. By incorporating submicrometer-sized graphene oxide nanosheets, we facilitated the ejection of 1.

View Article and Find Full Text PDF

Chlorpyrifos (CPF) is a broad-spectrum organophosphate insecticide. Long-term exposure to low levels of CPF is associated with neurodevelopmental and neurodegenerative disorders. The mechanisms leading to these effects are still not fully understood.

View Article and Find Full Text PDF

Van der Waals (vdW) contact has been widely regarded as one of the most potential strategies for exploiting low-resistance metal-semiconductor junctions (MSJs) based on atomically thin transition-metal dichalcogenides (TMDs), but this method is still not efficient due to weak metal-TMD interfacial interactions. Therefore, an understanding of interfacial interactions between metals and TMDs is essential for achieving low-resistance contacts with weak Fermi level pinning (FLP). Herein, we report how the interfacial interactions between metals and TMDs affect the electrical contacts by considering more than 90 MSJs consisting of a semiconducting TMD channel and different types of metal electrodes, including bulk metals, MXenes, and metallic TMDs.

View Article and Find Full Text PDF

Transient cortical beta-frequency oscillations associated with contextual novelty in high density mouse EEG.

Sci Rep

January 2025

Hatherly Laboratories, Department of Clinical and Biomedical Sciences, University of Exeter Medical School, University of Exeter, Prince of Wales Road, Exeter, EX4 4PS, UK.

Beta-frequency oscillations (20-30 Hz) are prominent in both human and rodent electroencephalogram (EEG) recordings. Discrete epochs of beta (or Beta2) oscillations are prevalent in the hippocampus and other brain areas during exploration of novel environments. However, little is known about the spatial distribution and temporal relationships of beta oscillations across the cortex in response to novel contexts.

View Article and Find Full Text PDF

TiN Boosting the Oxygen Reduction Performance of Fe-N-C through the Relay-Catalyzing Mechanism for Metal-Air Batteries.

ACS Appl Mater Interfaces

January 2025

Department of Aviation Oil and Material, Air Force Logistics Academy, 72 Xi Ge Road, Xuzhou, Jiangsu 221000, China.

Metal-air batteries desire highly active, durable, and low-cost oxygen reduction catalysts to replace expensive platinum (Pt). The Fe-N-C catalyst is recognized as the most promising candidate for Pt; however, its durability is hindered by carbon corrosion, while activity is restricted due to limited oxygen for the reaction. Herein, TiN is creatively designed to be hybridized with Fe-N-C (TiN/Fe-N-C) to relieve carbon corrosion and absorb more oxygen when catalyzing oxygen reduction.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!