Inter-observer variability and image quality are two key factors that can affect the diagnostic performance of elastography and B-mode ultrasound for breast tumor characterization. The purpose of this study is to use an image quantification method that automatically chooses a representative slice and then segments the tumor contour to evaluate the diagnostic features for tumor characterization. First, the representative slice is selected based on either the stiffness inside the tumor (the signal-to-noise ratio on the elastogram [SNRe]) or the contrast between the tumor and the surrounding normal tissue (the contrast-to-noise ratio on the elastogram [CNRe]). Next, the level set method is used to segment the tumor contour. Finally, the B-mode and elastographic features related to the segmented tumor are extracted for tumor characterization. The performance of the representative slice selected using the proposed methods is compared to that of the physician-selected slice in 151 biopsy-proven lesions (89 benign and 62 malignant). The diagnostic accuracies using elastographic features are 82.1% (124/151) for the slice with the maximum CNRe value, 82.1% (124/151) for the slice with the maximum SNRe value and 82.8% (125/151) for the physician-selected slice, whereas the diagnostic accuracies using B-mode features are 80.8% (122/151) for the slice with the maximum CNRe value, 87.4% (132/151) for the slice with the maximum SNRe value and 84.1% (127/151) for the physician-selected slice. When using both the B-mode and elastographic features to characterize the tumor, the accuracy of diagnosis is 86.1% (130/151) for the slice with the maximum CNRe value, 90.1% (136/151) for the slice with the maximum SNRe value and 89.4% (135/151) for the physician-selected slice. Our results show that the representative slice selected by SNRe and CNRe could be used to reduce the observer variability and to increase the diagnostic performance by the B-mode and elastographic features.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultrasmedbio.2013.01.017DOI Listing

Publication Analysis

Top Keywords

slice maximum
24
representative slice
20
physician-selected slice
20
slice
16
elastographic features
16
tumor characterization
12
slice selected
12
b-mode elastographic
12
maximum cnre
12
maximum snre
12

Similar Publications

Aim: The current study aims to delineate subcutaneous adipose tissue (SAT), visceral adipose tissue (VAT), the sacrospinalis muscle, and all abdominal musculature at the L3-L5 vertebral level from non-contrast computed tomography (CT) imagery using deep learning algorithms. Subsequently, radiomic features are collected from these segmented images and subjected to medical interpretation.

Materials And Methods: This retrospective analysis includes a cohort of 315 patients diagnosed with acute necrotizing pancreatitis (ANP) who had undergone comprehensive whole-abdomen CT scans.

View Article and Find Full Text PDF

Background And Objective: Cerebral aneurysms occur as balloon-like outpouchings in an artery, which commonly develop at the weak curved regions and bifurcations. When aneurysms are detected, understanding the risk of rupture is of immense clinical value for better patient management. Towards this, Fluid-Structure Interaction (FSI) studies can improve our understanding of the mechanics behind aneurysm initiation, progression, and rupture.

View Article and Find Full Text PDF

Background: Morphological and vascular characteristics of breast cancer can change during neoadjuvant chemotherapy (NAC). Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI)-acquired pre- and mid-treatment quantitatively capture information about tumor heterogeneity as potential earlier indicators of pathological complete response (pCR) to NAC in breast cancer.

Aims: This study aimed to develop an ensemble deep learning-based model, exploiting a Vision Transformer (ViT) architecture, which merges features automatically extracted from five segmented slices of both pre- and mid-treatment exams containing the maximum tumor area, to predict and monitor pCR to NAC.

View Article and Find Full Text PDF

Introduction: Scaphoid fractures are one of the most common carpal bone fractures, with most fractures involving the waist. When surgery is indicated, internal fixation with screws is the standard method for the fixation of these fractures. Accurate length and trajectory of the screw are two crucial parameters essential for optimal internal fixation.

View Article and Find Full Text PDF

Efficacy of Higher-Voltage Long-Duration Pulsed Radiofrequency for Spinal Zoster-Associated Pain: A Randomized Controlled Trial.

Pain Physician

December 2024

Department of Pain Management, West China Hospital/West China Tianfu Hospital, Sichuan University, Chengdu, Sichuan Province, China.

Article Synopsis
  • The study evaluates the safety and effectiveness of a higher-voltage long-duration pulsed radiofrequency (HL-PRF) treatment for managing zoster-associated pain (ZAP) compared to standard treatment.
  • Patients in Group A received gradually increased voltage up to 100 V, while Group B maintained a steady 65 V throughout.
  • Results focused on pain levels, emotional well-being, and quality of life over 12 weeks, with an aim to address high recurrence rates associated with the existing methods.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!