Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: This study measured swallowing threshold parameters and nutrient intake in partially dentate subjects rehabilitated by conventional free-end removable partial dentures (RPD) and by RPD over posterior implant retainers and ball attachments (BA).
Materials And Methods: Eight subjects (two men and six women; mean age 60.1 ± 6.6 years old) received conventional total maxillary dentures and free-end RPD in the mandible. Two months after denture insertion, swallowing threshold and nutrient intake assessments occurred, which included an evaluation of the number of masticatory cycles and medium particle size (X₅₀) of a silicone test material (Optocal). A 3-day food diary verified nutrient intake based on a standard Brazilian Food Composition Table. Then, osseointegrated implants were placed bilaterally in the mandibular first molar region, followed by BA, which was fitted in the RPD bases after healing. After 2 months of the RPD over implants and BA use, variables were again assessed. Wilcoxon signed rank tests evaluated the data (P < 0.05).
Results: Masticatory cycles did not differ (P > 0.05); however, subjects showed decreased X₅₀ values at the swallowing moment (P = 0.008) and increased daily energy (P = 0.008), carbohydrate (P = 0.016), protein (P = 0.023), calcium (P = 0.008), fiber (P = 0.016), and iron (P = 0.016) intake with RPD implants and BA inserts. No differences were found in fat consumption (P > 0.05).
Conclusion: Implants and BA retainers over a free-end RPD resulted in smaller swallowed median particle size and improved nutrient intake.