A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Implant retainers for free-end removable partial dentures affect mastication and nutrient intake. | LitMetric

Implant retainers for free-end removable partial dentures affect mastication and nutrient intake.

Clin Oral Implants Res

Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas, Campinas, Brazil.

Published: August 2014

Objectives: This study measured swallowing threshold parameters and nutrient intake in partially dentate subjects rehabilitated by conventional free-end removable partial dentures (RPD) and by RPD over posterior implant retainers and ball attachments (BA).

Materials And Methods: Eight subjects (two men and six women; mean age 60.1 ± 6.6 years old) received conventional total maxillary dentures and free-end RPD in the mandible. Two months after denture insertion, swallowing threshold and nutrient intake assessments occurred, which included an evaluation of the number of masticatory cycles and medium particle size (X₅₀) of a silicone test material (Optocal). A 3-day food diary verified nutrient intake based on a standard Brazilian Food Composition Table. Then, osseointegrated implants were placed bilaterally in the mandibular first molar region, followed by BA, which was fitted in the RPD bases after healing. After 2 months of the RPD over implants and BA use, variables were again assessed. Wilcoxon signed rank tests evaluated the data (P < 0.05).

Results: Masticatory cycles did not differ (P > 0.05); however, subjects showed decreased X₅₀ values at the swallowing moment (P = 0.008) and increased daily energy (P = 0.008), carbohydrate (P = 0.016), protein (P = 0.023), calcium (P = 0.008), fiber (P = 0.016), and iron (P = 0.016) intake with RPD implants and BA inserts. No differences were found in fat consumption (P > 0.05).

Conclusion: Implants and BA retainers over a free-end RPD resulted in smaller swallowed median particle size and improved nutrient intake.

Download full-text PDF

Source
http://dx.doi.org/10.1111/clr.12165DOI Listing

Publication Analysis

Top Keywords

nutrient intake
20
implant retainers
8
retainers free-end
8
free-end removable
8
removable partial
8
partial dentures
8
swallowing threshold
8
free-end rpd
8
masticatory cycles
8
particle size
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!