Direct membrane filtration is often used to concentrate viruses in water but it may suffer from severe membrane fouling and clogging. Here, a lanthanum-based flocculation method coupled with modified membrane filtration procedures was developed and evaluated to detect viruses in large volume (40 L) water samples. The lanthanum-based flocculation method could easily reduce the water sample volume by a factor of 40. Additional volume reduction was achieved by a two-step membrane filtration approach. First, selected membrane filters (including 1MDS electropositive filters and nitrocellulose electronegative filters-Millipore HATF filters) were used to reduce water sample volume further and compare their efficiencies in virus recovery. The Mg²⁺-modified HATF membrane performed better on MS2 retention with an average virus recovery of 83.4% (±4.5% [standard deviation]). After HATF membrane filtration and elution, centrifugal ultrafiltration through a 30 kDa cut-off membrane resulted in an overall concentration factor of 20,000. Results from the infectivity assay showed that the MS2 recovery efficiencies from the NanoCeram- and 1MDS-based direct filtration and the lanthanum-based concentration coupled with the modified filtration procedure were 10.1% (±1.0%), 3.3% (±0.1%), and 17.5% (±1.1%), respectively. Results from the PCR analysis showed that the virus recoveries of the lanthanum-based method were 20.6% (±2.9%) and 19.5% (±3.4%) for MS2 and adenovirus, respectively, while no adenovirus could be detected through the NanoCeram- and 1MDS-based direct filtration. The lanthanum-based concentration method coupled with modified membrane filtration procedures is therefore a promising method for detecting waterborne viruses.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jviromet.2013.03.017DOI Listing

Publication Analysis

Top Keywords

membrane filtration
24
coupled modified
16
modified membrane
12
filtration procedures
12
membrane
10
filtration
9
concentration method
8
lanthanum-based flocculation
8
flocculation method
8
method coupled
8

Similar Publications

Hyperbranched polyester amide/polyethersulphone mixed matrix nanofiltration membranes for contaminant rejection.

RSC Adv

January 2025

Packing and Packaging Materials Department, Institute of Chemical Industries Research, National Research Centre 33 El Behooth St., Dokki Giza Egypt +20 2 33371718.

Nanofiltration (NF) separation technology is a low-pressure filtration process, which is highly efficient and environmentally friendly. As a result, it has found wide application in water treatment. This work describes the preparation of flat sheet membranes the phase inversion method using blends of hyperbranched polyester amide (PEA) and polyether sulphone (PES) in definite ratios.

View Article and Find Full Text PDF

The endoplasmic reticulum (ER) is a vital organelle responsible for protein quality control, including the folding, modification, and transport of proteins. When misfolded or unfolded proteins accumulate in the ER, it triggers endoplasmic reticulum stress (ERS) and activates the unfolded protein response (UPR) to restore ER homeostasis. However, prolonged or excessive ERS can lead to apoptosis.

View Article and Find Full Text PDF

Effectiveness and safety of finerenone in membranous nephropathy patients: a retrospective, real‑world study.

Int Urol Nephrol

January 2025

Guangdong Provincial People's Hospital, Guangdong Cardiovascular Institute, Guangdong Academy of Medical Sciences, Guangdong, 510000, China.

Purpose: We aimed to conduct a retrospective analysis to assess the efficacy and safety of finerenone in patients with membranous nephropathy (MN).

Methods: This study conducted a retrospective analysis of patients with MN who were treated with finerenone for follow-up period ranging from 3 to 6 months. The study compared the estimated glomerular filtration rate (eGFR), urine total protein-to-creatinine ratio (PCR), urine albumin-to-creatinine ratio (ACR), serum creatinine concentration (SCr), blood pressure and serum potassium (K+) during the follow-up period.

View Article and Find Full Text PDF

Systemic lupus erythematosus (SLE) is a prevalent autoimmune condition worldwide resulting from the loss of tolerance against self-antigens. The constitutional symptoms of SLE are well-known, including fatigue, fever, myalgia, weight loss, arthralgia, arthritis, malar rash, and photosensitivity. These symptoms often overshadow the impacts SLE can have on all body systems, with the renal system frequently impacted.

View Article and Find Full Text PDF

An efficient, high-throughput enrichment system for the rapid detection of E. coli at low concentrations in water.

Anal Chim Acta

February 2025

School of Ophthalmology & Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, 130033, China; University of Chinese Academy of Sciences, Beijing, 100049, China; State Key Laboratory of Applied Optics, Changchun, 130033, China; Key Laboratory of Advanced Manufacturing for Optical Systems, Chinese Academy of Sciences, Changchun, 130033, China. Electronic address:

Certain virulent strains of Escherichia coli (E. coli), notably the enterohemorrhagic serotype O157:H7, are recognized for causing diarrhea, gastroenteritis, and a range of illnesses that pose significant risks to public health and the safety of drinking water supplies. Early detection and management of E.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!