This study was designed to measure the pressure distribution of the intervertebral disc under different degrees of distraction of the interspinous process, because of a suspicion that the degree of distraction of the spinous process may have a close relationship with the disc load share. Six human cadaver lumbar spine L2-L5 segments were loaded in flexion, neutral position, and extension. The L3-L4 disc load was measured at each position using pressure measuring films. Shape-memory interspinous process implants (SMID) with different spacer heights, ranging in size from 10 to 20 mm at 2 mm increments, were used. It was found that a SMID with a spacer height equal to the distance of the interspinous process in the neutral position can share the biomechanical disc load without a significant change of load in the anterior annulus. An interspinous process stabilizing device (IPD) would not be appropriate to use in those cases with serious spinal stenosis because the over-distraction of the interspinous process by the SMID would lead to overloading the anterior annulus which is a recognized cause of disc degeneration.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3596545PMC
http://dx.doi.org/10.1016/S1674-8301(10)60019-XDOI Listing

Publication Analysis

Top Keywords

interspinous process
24
disc load
12
distribution intervertebral
8
intervertebral disc
8
neutral position
8
smid spacer
8
anterior annulus
8
process
7
interspinous
6
disc
6

Similar Publications

Development and biomechanical evaluation of a 3D printed analogue of the human lumbar spine.

3D Print Med

January 2025

Musculoskeletal Biomechanics Research Lab, Department of Mechanical Engineering, McGill University, 845 Sherbrooke St. W (163), Montréal, QC, H3A 0C3, Canada.

Background: There exists a need for validated lumbar spine models in spine biomechanics research. Although cadaveric testing is the current gold standard for spinal implant development, it poses significant issues related to reliability and repeatability due to the wide variability in cadaveric physiologies. Moreover, there are increasing ethical concerns with human dissection practices.

View Article and Find Full Text PDF

Longitudinal DTI analysis of microstructural changes in lumbar nerve roots following Interspinous process device placement.

Magn Reson Imaging

December 2024

Neurology Unit, Department of Neurology and Human Movement Sciences, University Hospital of Siena, Siena, Italy; Department of Medical, Surgical and Neurological Science, University of Siena, Siena, Italy. Electronic address:

Diffusion tensor imaging (DTI) and its parameters such as fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), radial diffusivity (RD) are increasingly being used to assess peripheral nerve integrity alongside nerve conduction studies. This pilot study aims to compare DTI values of lumbar spinal nerve roots before (T0) and after (T1) treatment with an interspinous process device (IPD). Seven patients (5 females, 2 males; mean age: 68) suffering from neurogenic claudication and lumbar spinal canal and foraminal stenosis were evaluated.

View Article and Find Full Text PDF

Study Design: Reliability study.

Objectives: The radiographic diagnosis of non-union is not standardized. Prior authors have suggested using a cutoff of <1 mm interspinous process motion (ISPM) on flexion-extension radiographs, but the ability of practicing surgeons to make these measurements reliably is not clear.

View Article and Find Full Text PDF

Background And Objective: Recent studies have proposed computed tomography (CT) criteria for posterior ligamentous complex (PLC) injury: disrupted if ≥2 CT findings, indeterminate if single finding, and intact if 0 CT findings. The study aims to validate the CT criteria for PLC injury externally.

Methods: Three level 1 trauma centers enrolled 614 consecutive patients with acute thoracolumbar fractures (T1-L5) who received CT and MRI.

View Article and Find Full Text PDF

Introduction: Ewing sarcoma is a rare and highly aggressive malignancy, mostly involving the axial skeleton. Ewing sarcoma usually affects children and young adults under 20. Usually presenting as a painful swelling and discomfort worsening over time.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!