Endothelial cells in the peripheral circulation are rare events that require technically rigorous approaches for detection by flow cytometry. Visualization of these cells has been even more demanding, as this has historically required extensive enrichment and processing prior to attempting imaging. As a result, few, if any, examples exist on images of peripheral blood circulating endothelial cells (CECs) that include verification of the cell lineage both phenotypically and genomically. In this study, we have devised a method whereby CECs can be directly visualized after lysis of red blood cells and staining, without pre-enrichment or additional processing. Peripheral blood is stained with CD45, CD146, CD3, Hoechst, and DAPI to permit identification of CD146 positive, nonleukocyte, nucleated, and live cells that fit the description of CECs. These cells are imaged using the Amnis ImageStream(X), an imaging flow cytometer. Genomic verification of the endothelial nature of these cells is accomplished by using an aliquot of the same stained samples for sorting CECs using similar gating strategies. This proof of principle of direct imaging of CECs by imaging flow cytometry will permit studies to be conducted heretofore not possible, as the ImageStream(X) has the capability of detecting additional fluorochromes other than those used to identify the CECs. Such potential investigations include antigen colocalization or capping, autophagy and apoptosis, morphologic changes in response to therapy, and others. Thus, this method will enable a broad range of novel studies to be conducted using CECs as surrogates of the endothelium.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3819459PMC
http://dx.doi.org/10.1002/cyto.b.21088DOI Listing

Publication Analysis

Top Keywords

imaging flow
12
flow cytometry
12
endothelial cells
12
circulating endothelial
8
cells
8
peripheral blood
8
studies conducted
8
cecs
7
imaging
5
cytometry morphologic
4

Similar Publications

External delay and dispersion correction of automatically sampled arterial blood with dual flow rates.

Biomed Phys Eng Express

January 2025

Brain Health Imaging Centre, Centre for Addiction and Mental Health, B68-250 College St, Toronto, Ontario, M5T 1R8, CANADA.

Objective: Arterial sampling for PET imaging often involves continuously measuring the radiotracer activity concentration in blood using an automatic blood sampling system (ABSS). We proposed and validated an external delay and dispersion correction procedure needed when a change in flow rate occurs during data acquisition. We also measured the external dispersion constant of [11C]CURB, [18F]FDG, [18F]FEPPA, and [18F]SynVesT-1.

View Article and Find Full Text PDF

Accurate models for predicting drop dynamics, such as maximum drop departure sizes, are crucial for estimating heat transfer rates during condensation on superhydrophobic (SH) surfaces. Previous studies have focused on examining the heat transfer rates for SH surfaces under the influence of gravity or vapor flowing over the surface. This study investigates the impact of surface solid fraction and texture scale on drop mobility in a condensing environment with a humid air flow.

View Article and Find Full Text PDF

Transcranial Doppler sonography follow-up study in mild vascular cognitive impairment.

PLoS One

January 2025

Department of Medical and Surgical Sciences and Advanced Technologies "G. F. Ingrassia", University of Catania, Catania, Italy.

Background: To date, few data to transcranial Doppler sonography (TCD) are available in patients with mild vascular cognitive impairment (VCI) at risk for vascular or mixed dementia. In a previous study in patients with mild VCI and cerebral small vessels disease, a hemodynamic pattern of cerebral hypoperfusion and enhanced vascular resistance were observed; however, longitudinal data are currently lacking. Here, we perform a clinical, psychopathological, and neurosonological follow-up of patients with VCI in order to monitor any progression and to identify TCD measures to detect it.

View Article and Find Full Text PDF

Multifunctional Microflowers for Precise Optoacoustic Localization and Intravascular Magnetic Actuation In Vivo.

Adv Healthc Mater

January 2025

Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zürich, Winterthurerstrasse 190, Zurich, 8057, Switzerland.

Efficient drug delivery remains a significant challenge in modern medicine and pharmaceutical research. Micrometer-scale robots have recently emerged as a promising solution to enhance the precision of drug administration through remotely controlled navigation within microvascular networks. Real-time tracking is crucial for accurate guidance and confirmation of target arrival.

View Article and Find Full Text PDF

Background: Subcortical ischemic vascular dementia (SIVD) is a common subtype of vascular dementia. Currently, the bilateral common carotid artery stenosis (BCAS) mouse model is the most suitable SIVD rodent model. In this study, we investigated the functional and structural impairments in the hippocampus 1 month after BCAS.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!