A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

MR microscopy of the human finger and correlation with histology--a proof-of-principle study. | LitMetric

MR microscopy of the human finger and correlation with histology--a proof-of-principle study.

Clin Anat

Zentrum fuer Handchirurgie, Abteilung für Unfall- und Wiederherstellungschirurgie, Universitaetsmedizin Greifswald, Germany.

Published: September 2013

Magnetic resonance imaging (MRI) with small surface coils is a well established method for the diagnostic evaluation of finger masses. Until now, histological examination has been required to reliably assess tumor extent and infiltration of surrounding structures. Ultra-high-field MR microscopy (MRM) allows evaluation of anatomical structures and pathologies with submillimeter resolution. This study describes the diagnostic prospects and potential of MRM based on the ex-vivo examination of different finger pathologies. Ten human digits were examined by ex-vivo MRM at 7.1 Tesla (ClinScan, Bruker BioScan) using a T2-weighted turbo spin echo (TSE) sequence. Imaging parameters were: TE 48 ms; TR 8370 ms; slice thickness 700 µm; matrix size 1024 × 1024 pixels; FOV 37 × 37 mm; in-plane resolution 36 × 36 µm/voxel. Afterwards specimens were examined histologically. Histology and MRM were correlated. MRM allowed evaluation of the anatomy of the nail, the tendon insertions, the distal interphalangeal joint, and the neurovascular bundles. Finger abnormalities evaluated by MRM included osteomyelitis and metastatic disease. Subsequent histological examination confirmed MRM findings regarding origin, internal makeup, and extent of the structures visualized. This study demonstrates the potential of MRM for imaging small anatomical structures and pathologies of the human finger. Our ex-vivo findings correlate strongly with histology, suggesting that MRM may gain a central role in assessing anatomical structures and pathology in terms of morphology, extent, and infiltration of surrounding structures. Therefore, with increasing availability, MRM is expected to become an essential tool not only in experimental studies but also for daily routine.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ca.22232DOI Listing

Publication Analysis

Top Keywords

anatomical structures
12
mrm
10
human finger
8
histological examination
8
extent infiltration
8
infiltration surrounding
8
surrounding structures
8
structures pathologies
8
potential mrm
8
structures
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!