Aims: To clarify whether villous placental volumes in cases with low cord insertion (CI) are smaller than those with normal cord insertion.

Methods: A prospective cohort study was conducted to evaluate the association between location of umbilical CI and placental volume at 11 to 13 weeks' gestation. An ultrasound examination was performed to measure the crown-rump length, the distance between the histological internal cervical os and the CI site, the placental volume, and the uterine arterial blood flow. To standardize the distribution of the ultrasonographic measurements, we transformed data by crown-rump length-weighted linear regression.

Results: Six hundred fifty-nine subjects were analyzed. Scatter plots showed a slightly positive correlation between the z-scores of the distance from the CI site to the internal cervical os and villous placental volume (r = 0.102, p = 0.009) and a negative correlation between the z-scores of the villous placental volume and the uterine arterial pulsatility index (r = -0.165, p < 0.001) as well as the uterine arterial resistance index (r = -0.187, p < 0.001).

Conclusion: The placental volume was likely to be smaller in cases with CI located in the lower uterine segment.

Download full-text PDF

Source
http://dx.doi.org/10.1002/pd.4120DOI Listing

Publication Analysis

Top Keywords

placental volume
16
villous placental
12
location umbilical
8
internal cervical
8
volume uterine
8
uterine arterial
8
correlation z-scores
8
volume
5
placental
5
volume chorion
4

Similar Publications

Imaging of the Placenta.

Clin Obstet Gynecol

March 2025

Department of Obstetrics, Gynecology and Reproductive Sciences, School of Medicine, University of Maryland, College Park, Maryland.

Placental imaging is crucial in prenatal care, offering insights into both normal and abnormal pregnancies. Traditional methods like grayscale ultrasound and magnetic resonance imaging evaluate placental anatomy, whereas Doppler ultrasound is used for functional assessment. Recent advancements include functional magnetic resonance imaging and advanced Doppler software for demonstrating placental density and visualizing spiral arteries.

View Article and Find Full Text PDF

Prediction of pre-eclampsia using maternal hemodynamic parameters at 12 + 0 to 15 + 6 weeks.

Ultrasound Obstet Gynecol

January 2025

Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, SAR, China.

Objectives: To compare the maternal hemodynamic profile at 12 + 0 to 15 + 6 weeks' gestation in women who subsequently developed pre-eclampsia (PE) and those who did not, and to assess the screening performance of maternal hemodynamic parameters for PE in combination with the Fetal Medicine Foundation (FMF) triple test, including maternal factors (MF), mean arterial pressure (MAP), uterine artery pulsatility index and placental growth factor.

Methods: This was a prospective case-control study involving Chinese women with a singleton pregnancy who underwent preterm PE screening at 11 + 0 to 13 + 6 weeks' gestation using the FMF triple test, between February 2020 and February 2023. Women identified as being at high risk (≥ 1:100) for preterm PE by the FMF triple test were matched 1:1 with women identified as low risk (< 1:100) for maternal age ± 3 years, maternal weight ± 5 kg and date of screening ± 14 days.

View Article and Find Full Text PDF

Pregnancy Outcomes After Transvaginal Radiofrequency Ablation of Leiomyomas.

Obstet Gynecol

January 2025

Division of Minimally Invasive Surgery, Victoria Rey Clinic, Loyola University, Seville, Spain.

Objective: To evaluate pregnancy outcomes after transvaginal radiofrequency ablation of leiomyomas.

Methods: We conducted a retrospective review of the medical records of 226 pregnant patients after transvaginal radiofrequency ablation of leiomyomas from January 1, 2017, to February 28, 2022.

Results: Patients' mean age was 37.

View Article and Find Full Text PDF

Phase-contrast micro-tomography ([Formula: see text]CT) with synchrotron radiation can aid in the differentiation of subtle density variations in weakly absorbing soft tissue specimens. Modulation-based imaging (MBI) extracts phase information from the distortion of reference patterns, generated by periodic or randomly structured wavefront markers (e.g.

View Article and Find Full Text PDF

Amniotic fluid assessment is crucial in prenatal ultrasound to monitor fetal conditions, with polyhydramnios, characterized by excessive amniotic fluid, affecting 1%-2% of pregnancies. Polyhydramnios is linked to complications such as placental abruption, preterm labor, congenital anomalies, and postpartum hemorrhage, emphasizing the need for early detection and management. While idiopathic causes account for 60%-70% of cases, other causes include impaired fetal swallowing and increased urine production due to maternal, fetal, and placental conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!