Myogenic constrictor responses in small renal arteries and afferent arterioles are suppressed in mice with reduced levels of β-epithelial Na⁺ channel (βENaC(m/m)). The underlying mechanism is unclear. Decreased activity of voltage-gated calcium channels (VGCC) or mechanically gated ion channels and increased activity of large conductance calcium-activated potassium (BK) channels are a few possible mechanisms. The purpose of this study was to determine if VGCC, BK, or mechanically gated ion channel activity was altered in renal vascular smooth muscle cell (VSMC) from βENaC(m/m) mice. To address this, we used whole cell patch-clamp electrophysiological approaches in freshly isolated renal VSMCs. Compared with βENaC(+/+) controls, the current-voltage relationships for VGCC and BK activity are similar in βENaC(m/m) mice. These findings suggest neither VGCC nor BK channel dysfunction accounts for reduced myogenic constriction in βENaC(m/m) mice. We then examined mechanically gated currents using a novel in vitro assay where VSMCs are mechanically activated by stretching an underlying elastomer. We found the mechanically gated currents, predominantly carried by Na⁺, are observed with less frequency (87 vs. 43%) and have smaller magnitude (-54.1 ± 12.5 vs. -20.9 ± 4.9 pA) in renal VSMCs from βENaC(m/m) mice. Residual currents are expected in this model since VSMC βENaC expression is reduced by 50%. These findings suggest βENaC is required for normal mechanically gated currents in renal VSMCs and their disruption may account for the reduced myogenic constriction in the βENaC(m/m) model. Our findings are consistent with the role of βENaC as a VSMC mechanosensor and function of evolutionarily related nematode degenerin proteins.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3680677PMC
http://dx.doi.org/10.1152/ajprenal.00444.2012DOI Listing

Publication Analysis

Top Keywords

mechanically gated
24
gated currents
16
βenacm/m mice
16
renal vsmcs
12
βenac required
8
currents renal
8
renal vascular
8
vascular smooth
8
smooth muscle
8
vgcc mechanically
8

Similar Publications

We report a nonlinear terahertz (THz) detection device based on a metallic bull's-eye plasmonic antenna. The antenna, fabricated with femtosecond laser direct writing and deposited on a nonlinear gallium phosphide (GaP) crystal, focuses incoming THz waveforms within the sub-wavelength bull's eye region to locally enhance the THz field. Additionally, the plasmonic structure minimizes diffraction effects allowing a relatively long interaction length between the transmitted THz field and the co-propagating near-infrared gating pulse used in an electro-optic sampling configuration.

View Article and Find Full Text PDF

Objective: To establish an arterial spin labeling (ASL) protocol for rat livers that improves data reliability and reproducibility for perfusion quantification.

Methods: This study used respiratory-gated, single-slice, FAIR-based ASL imaging with multiple inversion times (TI) in rat livers. Quality assurance measures included: (1) introduction of mechanical ventilation to ensure consistent respiratory cycles by controlling the respiratory rate (45 bpm), tidal volume (10 ml/kg), and inspiration: expiration ratio (I:E ratio, 1:2), (2) optimization of the trigger window for consistent trigger points, and (3) use of fit residual map and coefficient of variance as metrics to assess data quality.

View Article and Find Full Text PDF

In coal mining operations, the stable operation of hydraulic supports is crucial for ensuring mine safety. However, the nonlinear, non-stationary characteristics and noise interference in hydraulic support pressure data pose significant challenges for anomaly detection and fault diagnosis. This study proposes an anomaly detection and failure identification method based on Gated Recurrent Unit Autoencoder (GRU-AE), aimed at achieving anomaly detection in hydraulic support pressure data and equipment failure early warning.

View Article and Find Full Text PDF

Extracellular vesicles (EVs) are associated with intercellular communications, immune responses, viral pathogenicity, cardiovascular diseases, neurological disorders, and cancer progression. EVs deliver proteins, metabolites, and nucleic acids into recipient cells to effectively alter their physiological and biological response. During their transportation from the donor to the recipient cell EVs face differential ionic concentrations, which can be detrimental to their integrity and impact their cargo content.

View Article and Find Full Text PDF

The heart is a dynamic pump whose function is influenced by its mechanical properties. The viscoelastic properties of the heart, i.e.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!