A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

New insights into the aspects of pulmonary diffusing capacity in Fontan patients. | LitMetric

AI Article Synopsis

  • Patients with a functionally univentricular heart, post-Fontan procedure, show reduced pulmonary diffusing capacity primarily due to lower pulmonary capillary blood volume, despite having a preserved alveolar capillary membrane diffusing capacity.
  • Advanced pulmonary function tests indicated that supine positioning significantly increased diffusing capacity and pulmonary capillary blood volume in Fontan patients compared to healthy controls.
  • The resting cardiac index emerged as a key independent predictor of pulmonary diffusing capacity in the studied population.

Article Abstract

Background: Patients with a functionally univentricular heart, palliated a.m. Fontan, consequently have non-pulsatile pulmonary blood flow and are known to have a reduced pulmonary diffusing capacity. However, the cause of this reduction remains unclear. We aimed to assess the possible determinants in the aetiology of a reduced diffusing capacity and also to assess whether it could be increased. Furthermore, we aimed to search for predictors of a reduced diffusing capacity.

Material And Methods: A total of 87 Fontan patients (mean age 16.3 ± 7.6 years) performed advanced pulmonary function tests and maximal cycle ergometer tests. A total of 10 Fontan patients and nine matched controls performed a supine pulmonary function test after a supine rest.

Results: In the sitting pulmonary function test, the mean z-scores were: diffusing capacity, 2.38 ± 1.20; pulmonary capillary blood volume, 2.04 ± 0.80; and alveolar capillary membrane diffusing capacity, 0.14 ± 0.84. In the supine compared with the sitting pulmonary function test, the diffusing capacity increased by 51.7 ± 11.9% in the Fontan group and by 23.3 ± 17.7% in the control group (p < 0.001); moreover, the pulmonary capillary blood volume increased by 48.3 ± 17.4% in the Fontan group and by 20.2 ± 13.9% in the control group (p = 0.001). In a multiple linear regression analysis including the explanatory variables of surgical data and exercise data at rest and peak exercise, the resting cardiac index was an independent predictor of the diffusing capacity (regression coefficient: 0.18, p < 0.001).

Conclusions: The pulmonary diffusing capacity was reduced in Fontan patients because of a reduced pulmonary capillary blood volume, whereas the alveolar capillary membrane diffusing capacity was preserved. The diffusing capacity was highly increasable in Fontan patients compared with controls, and the resting cardiac index was an independent predictor of the diffusing capacity.

Download full-text PDF

Source
http://dx.doi.org/10.1017/S1047951113000358DOI Listing

Publication Analysis

Top Keywords

diffusing capacity
44
fontan patients
20
pulmonary function
16
diffusing
12
pulmonary diffusing
12
function test
12
pulmonary capillary
12
capillary blood
12
blood volume
12
pulmonary
11

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!