Reverse activated hyrax pressure appliance for treatment of a keloid located at auricula helix.

J Prosthodont

Department of Prosthodontics, School of Dentistry, Istanbul Medipol University, Turkey.

Published: August 2013

Keloids are considered aberrations of the wound healing process, and various treatment regimens are described depending on the morphology and size of the lesion. Compression therapy using custom-made pressure clips or splints is widely used for the treatment of keloids. The most common complication of this therapy is ulceration due to excessive soft tissue pressure, resulting in delays and prolonged treatment time. This article describes the fabrication of a custom-made pressure appliance for the treatment of a keloid located at the auricle helix. The pressure appliance can be modified to fit the auricle helix and covers the area needing pressure.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jopr.12034DOI Listing

Publication Analysis

Top Keywords

pressure appliance
12
appliance treatment
8
treatment keloid
8
keloid located
8
custom-made pressure
8
auricle helix
8
pressure
6
treatment
5
reverse activated
4
activated hyrax
4

Similar Publications

The intra-aortic balloon pump (IABP) is a widely-used mechanical circulatory support device that enhances hemodynamics in patients with heart conditions. Although the IABP is a common clinical tool, its effectiveness in enhancing outcomes for patients with acute myocardial infarction and cardiogenic shock remains disputed. This study aimed to assess the effectiveness of intra-aortic dual-balloon pump (IADBP) and its impact on aortic hemodynamics compared with an IABP.

View Article and Find Full Text PDF

Labyrinth seals (LSs) in turbomachinery are used to minimize leaks. This study presents an experimental setup designed to test and validate LS designs. The test bench (TB) described in this paper can evaluate different LS designs obtained through various methods to find better solutions to mitigate greenhouse gas (GHG) emissions.

View Article and Find Full Text PDF

Purpose: To report on in-vivo intrarenal pressure (IRP) during flexible ureteroscopy for treatment of kidney stones while using the novel flexible and navigable suction ureteral access sheath (FANS).

Methods: A retrospective observational analysis was performed for 25 patients undergoing routine flexible ureteroscopy for treatment of renal stones between February 2024 and June 2024 from two centres in Canada. The LithoVue Elite™ ureteroscope (Boston Scientific Corp.

View Article and Find Full Text PDF

Aerodynamic performance enhancement of centrifugal compressor using numerical techniques.

F1000Res

January 2025

Department of Aeronautical & Automobile Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.

Background: Centrifugal compressors are dynamic machines utilizing a rotating impeller, efficiently accelerate incoming gases, transforming kinetic energy into pressure energy for compression. They serve a wide range of industries, including air conditioning, refrigeration, gas turbines, industrial processes, and applications such as air compression, gas transportation, and petrochemicals, demonstrating their versatility. Designing a centrifugal compressor poses challenges related to achieving high aerodynamic efficiency, surge and choke control, material selection, rotor dynamics, cavitation, erosion, and addressing environmental considerations while balancing costs.

View Article and Find Full Text PDF

Typical waveforms used for the simulation of pressure and volume-controlled ventilation in medical ventilators have been extensively studied in the literature. The majority of simulation studies reported employ the step pattern or ramp pattern to model the pressure and flow variations in pressure/volume-controlled ventilation. It was observed that the above waveforms tend to add to the discomfort level of patients due to the presence of jerks in derivatives of pressure/flow variations; the pressure/flow variation of air and oxygen mixture should be smooth so that the patient discomfort is kept at a minimal level.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!