Two methods for the determination of cadmium and lead based on graphite furnace atomic absorption spectrometry (GFAAS) with Zeeman background correction are described. The main difference between the methods is the method of sample destruction, bomb digestion versus dry ashing. The precision and accuracy of the methods has been tested by analysing 16 different reference materials, with cadmium concentrations varying from 2.9 micrograms/kg to 2.7 mg/kg and lead concentrations from 44 micrograms/kg to 13.5 mg/kg. The methods produced results which differ, with a few exceptions, less than 10% from the certified contents, with relative standard deviations of around 5%. The methods are not difficult to carry out, are not very laborious and without modifications are applicable to a large variety of products. The sample solutions obtained can also be used for the determination of other elements, e.g. Al, Cr, Cu, Hg, Mn, Ni and Zn. The detection limits, for test portions of 1 and 5 g (wet products) are 0.5-1 microgram/kg for cadmium and 5-20 micrograms/kg for lead.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/02652039009373891 | DOI Listing |
Ecotoxicol Environ Saf
January 2025
College of Bioscience and Biotechnology, Hunan Agricultural University, Changsha 410128, China; Yuelushan Laboratory, Changsha 410125, China. Electronic address:
Soil heavy metal pollution presents substantial risks to food security and human health. This study focused on the efficiency of plant growth-promoting fungus-Beauveria bassiana FE14 and Miscanthus floridulus on the synergistic remediation of soil Cd contamination. Results revealed that B.
View Article and Find Full Text PDFPeerJ
January 2025
Facultad de Ingeniería Química, Universidad Michoacana de San Nicolás de Hidalgo, Morelia, Michoacán, Mexico.
The average annual water availability worldwide is approximately 1,386 trillion cubic hectometers (hm), of which 97.5% is saltwater and only 2.5% is freshwater.
View Article and Find Full Text PDFAnal Bioanal Chem
January 2025
Turkish Petroleum Refineries Co. TÜPRAŞ R&D Center, Körfez, Kocaeli, 41790, Türkiye.
Monoelemental calibration solutions are the most common reference in elemental analysis, linking measurement results to the International System of Units (SI). National Metrology Institutes (NMI) prepare these solutions as certified reference materials (CRM) and determine their elemental mass fraction with high accuracy. Characterization with high accuracy is one of the most critical steps in CRM production.
View Article and Find Full Text PDFEnviron Health
January 2025
Department of Family Medicine, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan.
DNA methylation is a critical step in brain development, 5-Methyl-2'-deoxycytidine (5mdC) is one of the global DNA methylation markers. Arsenic and lead exposures have been associated with neurotoxicity, which may be linked to epigenetic changes. Our research sought to investigate the correlation between 5mdC and developmental delay (DD) among preschoolers.
View Article and Find Full Text PDFFront Antibiot
April 2024
Transmission, Reservoir and Diversity of Pathogens Unit, Institut Pasteur, Les Abymes, France.
Introduction: This study aimed to understand the origin and to explain the maintenance of extended-spectrum β-lactamase (ESBL) isolated from food-producing animals in a third-generation cephalosporin (3GC)-free farm.
Methods: Culture and molecular approaches were used to test molecules other than 3GC such as antibiotics (tetracycline and oxytetracycline), antiparasitics (ivermectin, flumethrin, fenbendazol, and amitraz), heavy metal [arsenic, HNO, aluminum, HNO, cadmium (CdSO), zinc (ZnCl), copper (CuSO), iron (FeCl), and aluminum (AlSO)], and antioxidant (butylated hydroxytoluene) as sources of selective pressure. Whole-genome sequencing using short read (Illumina™) and long read (Nanopore™) technologies was performed on 34 genomes.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!