Purpose: Biologic grafts are rarely used for inguinal herniorrhaphy. The aim of this study was to compare the clinical outcomes between patients undergoing a Lichtenstein's hernioplasty with a porcine mesh versus a standard synthetic.

Methods: A prospective, randomized, double-blinded multicenter, evaluation of inguinal hernia repair was conducted between 2008 and 2010. Lichtenstein hernioplasty was performed using Strattice™ or lightweight polypropylene (Ultrapro) mesh. Quality of life, pain, overall complication rate, and recurrence were measured.

Results: One hundred and seventy-two patients were randomized to Strattice™ (n = 84) or Ultrapro (n = 88). At 3 months postoperatively, there were no differences on the occurrence or type of wound events [RR: 0.98 (95% CI 0.52-1.86, p = 0.69), Strattice™ (15 events) vs. Ultrapro (16 events)]. The mean level of impairment caused by the hernia, assessed by Activities Assessment Scale (AAS), significantly decreased postoperatively in both groups at 3 months (31% Strattice™ and 37% Ultrapro). Patients in the Strattice group reported significantly less postoperative pain during postoperative days 1 through 3 compared to Ultrapro patients. However, the amount of postoperative pain at 3 months, as assessed by the mean worst pain score on a visual analog scale and the Brief Pain Index, was similar between groups (95% CI 1.0-29.3). No hernia recurrences were observed in either group.

Conclusions: Strattice™ is safe and effective in repairing inguinal hernia, with comparable intra-operative and early postoperative morbidity to synthetic mesh. Long-term follow-up is necessary in order to know whether the clinical outcomes of Strattice are equivalent to standard synthetic mesh in patients undergoing Lichtenstein's hernioplasty.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10029-013-1076-9DOI Listing

Publication Analysis

Top Keywords

synthetic mesh
12
clinical outcomes
8
patients undergoing
8
undergoing lichtenstein's
8
lichtenstein's hernioplasty
8
inguinal hernia
8
ultrapro patients
8
postoperative pain
8
strattice™
6
mesh
5

Similar Publications

Aim: Ventral mesh rectopexy (VMR) is an established surgical treatment for rectal prolapse and outlet obstruction. In contrast to continental Europe, in the UK and US the use of synthetic mesh has been abandoned in favour of biologic mesh, due to concerns regarding mesh related morbidity. The current study investigated if either material is superior, in terms of clinical recurrence and mesh related complications.

View Article and Find Full Text PDF

Natural and synthetic biopolymers are gaining popularity in the development of inhaled drug formulations. Their highly tunable properties and ability to sustain drug release allow for the incorporation of attributes not achieved in dry powder inhaler formulations composed only of micronized drugs, standard excipients, and/or carriers. There are multiple physiological barriers to the penetration of inhaled drugs to the epithelial surface, such as the periciliary layer mucus mesh, pulmonary macrophages, and inflammation and mucus compositional changes resulting from respiratory diseases.

View Article and Find Full Text PDF

The abdominal wall is an uncommon site for endometriosis that occurs in the soft tissues of the wound site after laparotomy. The present study reviewed cases of post-cesarean section abdominal wall endometriosis that were surgically treated at our institution from April 2007 to August 2020. We analyzed data from nine patients who were diagnosed with abdominal wall endometriosis and selected surgery after receiving sufficient explanation of hormone therapy and from patients who reported no improvement in symptoms with hormone therapy.

View Article and Find Full Text PDF

Abdominal PP meshes coated with functional core-sheath biodegradable nanofibers with anticoagulant and antibacterial properties.

Biomater Adv

January 2025

Univ. Lille, CNRS, INRAE, Centrale Lille, UMR 8207 - UMET - Unité Matériaux et Transformations, F-59000 Lille, France. Electronic address:

Abdominal hernia repair is a common surgical procedure, involving in most cases the use of textile meshes providing a mechanical barrier to consolidate the damaged surrounding tissues and prevent the resurgence of the hernia. However, in more than half cases postoperative complications such as adhesions and infections occur at the surface of the mesh, leading to chronic pain for the patient and requiring the removal of the implant. One of the most promising strategies to reduce the risk of postoperative adhesions and infections is to add a physical barrier between the mesh and the abdominal walls.

View Article and Find Full Text PDF

This study presents an advanced methodology for 3D heart reconstruction using a combination of deep learning models and computational techniques, addressing critical challenges in cardiac modeling and segmentation. A multi-dataset approach was employed, including data from the UK Biobank, MICCAI Multi-Modality Whole Heart Segmentation (MM-WHS) challenge, and clinical datasets of congenital heart disease. Preprocessing steps involved segmentation, intensity normalization, and mesh generation, while the reconstruction was performed using a blend of statistical shape modeling (SSM), graph convolutional networks (GCNs), and progressive GANs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!