Volumetric analysis of simulated alveolar cleft defects and bone grafts using cone beam computed tomography.

Plast Reconstr Surg

Dallas, Texas; Cleveland, Ohio; and Chicago, Ill. From the Department of Plastic Surgery, University of Texas Southwestern Medical Center; the Departments of Plastic Surgery and Orthodontics, School of Dental Medicine, Case Western Reserve University; and the Division of Pediatric Plastic Surgery, Lurie Children's Hospital, Northwestern University Feinberg School of Medicine.

Published: April 2013

Background: Cone beam computed tomography allows for a significantly lower radiation dose than conventional computed tomographic scans, with generation of accurate images of the maxillofacial skeleton. The authors investigated its accuracy in the volumetric analysis of alveolar cleft defects and simulated bone grafts.

Methods: Five simulated alveolar clefts were created using a burr drill in three dry pediatric skulls and filled with simulated bone grafts. Pregrafting and postgrafting cone beam computed tomographic scanning of skulls was performed using specialized imaging software. The authors compared actual volumes of the simulated bone grafts obtained using a water displacement technique with scan-derived volumes of both the grafts and the defects.

Results: The average of the five simulated bone grafts calculated by cone beam computed tomography scanning was 0.380 ml, which was lower than their mean volume of 0.392 ml calculated by water displacement. The percentage difference between measurements ranged from 2.9 to 8.6 percent (mean, 4.86 percent). The mean of the simulated defects of 0.399 ml derived from scanning was higher than the actual mean volume of 0.392 ml derived by water displacement. The mean difference in defect comparison was 2.52 percent. There was no statistically significant difference between real volume and scan-derived graft and defect volume.

Conclusions: Cone beam computed tomography calculation of simulated alveolar cleft and bone graft volume is precise and accurate. The volume of bone graft needed to fill alveolar defects can be accurately predicted using volume measurements of the bony defect. These findings further validate its use in the perioperative assessment of alveolar grafting.

Download full-text PDF

Source
http://dx.doi.org/10.1097/PRS.0b013e3182818e4fDOI Listing

Publication Analysis

Top Keywords

cone beam
20
beam computed
20
bone grafts
16
computed tomography
16
simulated bone
16
simulated alveolar
12
alveolar cleft
12
water displacement
12
volumetric analysis
8
simulated
8

Similar Publications

Objectives: To investigate the influence of different facial scanners and integration approaches on the accuracy of virtual dental patients (VDPs).

Methods: Forty VDPs were generated using a head mannequin and two facial scanners: 1) an industrial scanner and 2) a smartphone scanner. For each scanner, two integration methods were applied: 1) integration by virtual facebow scan and 2) integration by nose-teeth scan.

View Article and Find Full Text PDF

Objectives: To investigate the performance of a deep learning (DL) model for segmenting cone-beam computed tomography (CBCT) scans taken before and after mandibular horizontal guided bone regeneration (GBR) to evaluate hard tissue changes.

Materials And Methods: The proposed SegResNet-based DL model was trained on 70 CBCT scans. It was tested on 10 pairs of pre- and post-operative CBCT scans of patients who underwent mandibular horizontal GBR.

View Article and Find Full Text PDF

Introduction: The temporomandibular joint (TMJ) is one of the most intricate anatomical entities within the human body and is clinically relevant in the field of dentistry. Therefore, the present study aimed to conduct a three-dimensional (3D) volumetric comparison of the TMJ space in skeletal Class I and II patients using cone-beam computed tomography (CBCT).

Materials And Methods: This cross-sectional, retrospective study was conducted on 40 CBCT records divided into skeletal Class I and skeletal Class II patients.

View Article and Find Full Text PDF

Background: Chronic apical periodontitis (AP) may influence the outcome of root canal treatment. Thus, it is important to diagnose AP using the best method available. This research was done to compare the diagnostic accuracy of parallel periapical radiography (PR) and different field of views (FOVs) of cone-beam computed tomography (CBCT).

View Article and Find Full Text PDF

Background And Purpose: A novel ring-gantry cone-beam computed tomography (CBCT) imaging system shows improved image quality compared to its conventional version, but its effect on autosegmentation is unknown. This study evaluates the impact of this high-performance CBCT on autosegmentation performance, inter-observer variability, contour correction times and delineation confidence, compared to the conventional CBCT.

Materials And Methods: Twenty prostate cancer patients were enrolled in this prospective clinical study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!