Object: Anatomical variability of the C-2 pedicle poses a challenge for C-2 fixation. The use of multidimensional CT scanning is not widely used but might be an asset to preoperative planning. Careful preoperative planning is imperative for instrumentation at C-2. Fine-cut, noncontrast CT scanning is a useful tool for delineating anatomy; however, the axis of the images is not always along the anatomical axis of the vertebra in question. The authors evaluated the suitability of C-2 pedicles for screw placement by using OsiriX (Pixmeo) software to change the gantry angle of CT angiograms to measure the anatomical dimensions of the C-2 pedicle.

Methods: The authors conducted a retrospective review of CT angiograms of the head and neck from 47 trauma patients seen consecutively at George Washington University Hospital. For each patient, 3 independent observers determined length and width of each C-2 pedicle (94 samples) by using OsiriX. OsiriX is a DICOM viewer that enables navigation and visualization in multidimensional imaging, such as 3D imaging, which was used for this study. Sex-specific measurements were also determined. Vertebral anatomy was studied to determine whether aberrant anatomy would preclude pedicle fixation. Statistical analyses were performed.

Results: Of the 47 patients, 27 were male. Overall mean C-2 pedicle widths and lengths were 8.272 ± 1.364 mm and 27.052 ± 3.471 mm, respectively. The average widths and lengths of the pedicle in female patients were 8.040 ± 1.262 mm and 27.241 ± 2.731 mm, respectively, and those in male patients were 8.444 ± 1.414 mm and 26.913 ± 3.933 mm, respectively. The sex difference was statistically significant for width (p = 0.012) but not for length (p = 0.41). On the basis of width, the percentages of pedicles that could tolerate a 3.5-mm and 4.0-mm screw were 98% and 97%, respectively. Vertebral anatomy precluded screw length greater than 14 mm for only 3 patients.

Conclusions: Using multidimensional CT or 3D imaging, the authors found that C-2 pedicles in over 90% of patients could tolerate 3.5-mm and 4.0-mm pedicle screws. Vertebral anatomy precluded use of screw lengths greater than 14 mm for only 3 (6%) of 47 patients. Therefore, the C-2 pedicle might be more tolerant of fixation than previously reported.

Download full-text PDF

Source
http://dx.doi.org/10.3171/2013.2.SPINE12798DOI Listing

Publication Analysis

Top Keywords

c-2 pedicle
20
vertebral anatomy
12
c-2
10
pedicle
8
preoperative planning
8
c-2 pedicles
8
multidimensional imaging
8
widths lengths
8
tolerate 35-mm
8
35-mm 40-mm
8

Similar Publications

Background Vertebral hemangiomas (VHs) are benign vascular tumors commonly found within the vertebral bodies of the spine. While most VHs remain asymptomatic and are often discovered incidentally during imaging studies, a subset can become symptomatic, leading to clinical challenges. The optimal treatment approach for symptomatic VHs remains a topic of debate.

View Article and Find Full Text PDF

Objective: To compare the effectiveness of robot-assisted and traditional freehand screw placement in the treatment of atlantoaxial dislocation.

Methods: The clinical data of 55 patients with atlantoaxial dislocation who met the selection criteria between January 2021 and January 2024 were retrospectively analyzed. According to different screw placement methods, they were divided into the traditional group (using the traditional freedhand screw placement, 31 cases) and the robot group (using the Mazor X robot-assisted screw placement, 24 cases).

View Article and Find Full Text PDF

Objective: Successful outcomes in head and neck surgery rely on maintaining perfusion in pedicled skin flaps. Thermal imaging offers a noninvasive means to assess tissue perfusion, potentially aiding in predicting flap viability. This pilot study explores the utility of SBTI (smartphone-based thermal imaging) for predicting flap vitality and monitoring during surgery.

View Article and Find Full Text PDF

Introduction: Pedicle screw placement is a widely accepted surgical procedure for spinal fixation. Despite increases in knowledge about and expertise in pedicle screw insertion techniques, overall reported screw misplacement rates are still high. Spinal neuronavigation and intraoperative computed tomography (CT) imaging improves the accuracy and safety of pedicle screw placement through the continuous monitoring of screw trajectory.

View Article and Find Full Text PDF
Article Synopsis
  • The study analyzed the safety and effectiveness of using vertebral artery mobilization to place C pedicle screws in 12 patients with high-riding vertebral arteries who underwent surgery for spinal issues.
  • Results showed successful placement of screws without injuring the vertebral artery, with no severe complications and all patients achieving bone fusion after six months.
  • Preoperative and postoperative assessments indicated significant improvements in spinal alignment, as demonstrated by a decrease in the anterior atlantodental interval and other key measurements.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!