Synergy stems are tapered stems featuring a proximal porous coating, grid blasting below the proximal third to the distal end. This study included 41 patients (50 hips) who underwent total hip arthroplasty with follow-ups for 10 years or more. No stem reimplantations were performed. Spot welds were observed in the distal stem in Gruen zones 3 and 5 in 35 and 32 hips, respectively. First-degree stress shielding occurred in 8 hips; 2nd-degree, 20 hips; 3rd-degree, 13 hips; and 4th-degree, 9 hips. Because of bone fixation to the distal grit-blasted section of the stem, severe stress shielding was observed in nearly half of the cases. Multiple regression analysis of stress shielding determinants revealed a correlation between stem size and short patient height, showing the cause of stress shielding to be a mismatch in size between the stem and the femoral bone.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2013.02.027DOI Listing

Publication Analysis

Top Keywords

stress shielding
20
total hip
8
hip arthroplasty
8
severe stress
8
stem
7
hips
6
stress
5
shielding
5
follow-up 10-12
4
10-12 years
4

Similar Publications

X-ray Responsive Antioxidant Drug-Free Hydrogel for Treatment of Radiation Skin Injury.

ACS Appl Mater Interfaces

January 2025

State Key Laboratory of Advanced Medical Materials and Devices, Tianjin Key Laboratory of Radiation Medicine and Molecular Nuclear Medicine, Key Laboratory of Radiopharmacokinetics for Innovative Drugs, Tianjin Institutes of Health Science, Institute of Radiation Medicine, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, P. R. China.

Radiotherapy (RT) is widely applied in tumor therapy, but inevitable side effects, especially for skin radiation injury, are still a fatal problem and life-threatening challenge for tumor patients. The main components of topical radiation protection preparations currently available on the market are antioxidants, such as SOD, which are limited by their unstable activity and short duration of action, making it difficult to achieve the effects of radiation protection and skin radiation damage treatment. Therefore, we designed a drug-free antioxidant hydrogel patch with encapsulated bioactive epidermal growth factor (EGF) for the treatment of radiation skin injury.

View Article and Find Full Text PDF

Background: Total knee arthroplasty (TKA) is one of the most common orthopaedic procedures and the number of patients which undergo TKA will continue to rise in the coming years. Consecutively, the number of necessary revision surgeries will increase. One of the main reasons for revision surgery is aseptic loosening because of a so-called stress-shielding effect.

View Article and Find Full Text PDF

Stress Granule Induction in Rat Retinas Damaged by Constant LED Light.

Invest Ophthalmol Vis Sci

January 2025

Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Departamento de Química Biológica Ranwel Caputto. Córdoba, Argentina.

Purpose: Stress granules (SGs) are cytoplasmic biocondensates formed in response to various cellular stressors, contributing to cell survival. Although implicated in diverse pathologies, their role in retinal degeneration (RD) remains unclear. We aimed to investigate SG formation in the retina and its induction by excessive LED light in an RD model.

View Article and Find Full Text PDF

Hydraulic fracturing, which forms complex fracture networks, is a common technique for efficiently exploiting low-permeability conglomerate reservoirs. However, the presence of gravel makes conglomerate highly heterogeneous, endowing the deformation, failure, and internal micro-scale fracture expansion mechanisms with uniqueness. The mechanism of fracture expansion when encountering gravel in conglomerate reservoirs remains unclear, challenging the design and effective implementation of hydraulic fracturing.

View Article and Find Full Text PDF

Dental titanium implants and their surface modifications markedly improve implant biocompatibility. However, studies evaluating the mechanical biocompatibility of implants are scarce. In particular, the analysis of mechanical biocompatibility deficiencies leading to stress shield-induced bone resorption.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!