Purpose: To develop a new schematic scheme for efficiently recording the key parameters of gas permeable contact lens (GP) fits based on current consensus.
Methods: Over 100 established GP fitters and educators met to discuss the parameters proposed in educational material for evaluating GP fit and concluded on the key parameters that should be recorded. The accuracy and variability of evaluating the fluorescein pattern of GP fit was determined by having 35 experienced contact lens practitioners from across the world, grading 5 images of a range of fits and the topographer simulation of the same fits, in random, order using the proposed scheme. The accuracy of the grading was compared to objective image analysis of the fluorescein intensity of the same images.
Results: The key information to record to adequately describe the fit of an GP was agreed as: the manufacturer, brand and lens parameters; settling time; comfort on a 5 point scale; centration; movement on blink on a ±2 scale; and the Primary Fluorescein Pattern in the central, mid-peripheral and edge regions of the lens averaged along the horizontal and vertical lens axes, on a ±2 scale. On average 50-60% of practitioners selected the median grade when subjectively rating fluorescein intensity and this was correlated to objective quantification (r=0.602, p<0.001). Objective grading suggesting horizontal median fluorescein intensity was generally symmetrical, as was the vertical meridian, but this was not the case for subjective grading. Simulated fluorescein patterns were subjectively and objectively graded as being less intense than real photographs (p<0.01).
Conclusion: GP fit recording can be standardised and simplified to enhance GP practice.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.clae.2013.02.003 | DOI Listing |
Ophthalmologie
January 2025
Klinik für Augenheilkunde, Klinikum Chemnitz, Flemmingstr. 2, 09116, Chemnitz, Deutschland.
Background: Damage induced by ultraviolet (UV) radiation plays a decisive role in the carcinogenesis of malignant tumors of the eyelids.
Methods: A selective literature search was performed in PubMed and Google Scholar.
Results: Large epidemiological studies show an increase in the prevalence of eyelid tumors in recent decades.
Cornea
January 2025
Department of Ophthalmology, Rothschild Foundation, Paris, France; and.
Purpose: The purpose of this study was to investigate the effect of hypoxia and hypobaric conditions on refraction and central corneal thickness on healthy corneas during an ascent without oxygen supplementation above 7000 m (23 000 ft).
Methods: Twelve multinational mountaineers were included in a prospective observational cohort study during an expedition to the Korzhenevskoi Peak (7105 m). The two patients excluded from the study had a history with keratoconus or were current wearers of rigid contact lenses.
Clin Exp Optom
January 2025
Eurolens Research, Division of Pharmacy and Optometry, The University of Manchester, Manchester, UK.
Clinical Relevance: Knowledge of contact lens prescribing trends can (a) assist practitioners to benchmark their own prescribing habits, (b) help the contact lens industry understand preferred products, and (c) support academics in scholarly writings.
Background: This work aims to document contact lens prescribing trends in Australia over the past quarter of a century.
Methods: An annual survey of contact lens prescribing trends was conducted in Australia each year from 2000 to 2024, inclusive, by asking optometrists to provide information relating to 10 consecutive contact lens fits undertaken between January and March.
J Control Release
January 2025
Oujiang Laboratory (Zhejiang Lab for Regenerative Medicine, Vision and Brain Health), Cixi Biomedical Research Institute, School of Pharmaceutical Sciences, Wenzhou Medical University, Ningbo, China. Electronic address:
Severe corneal injuries can cause visual impairment even blindness. Surgically stitching or implanting biomaterials have been developed, but their implementation requires professional surgeons, failing to address the immediate need of medical treatment. The pressing challenge lies in developing multifunctional biomaterials that enable self-management of corneal injuries.
View Article and Find Full Text PDFCont Lens Anterior Eye
January 2025
State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, China. Electronic address:
Purpose: To develop a Chinese version of the 8-item Contact Lens Dry Eye Questionnaire (CLDEQ-8) with cross-cultural adaption and clinical validation among soft contact lens wearers (SCL) in China.
Methods: The translation and adaptation of the Chinese CLDEQ-8 (C-CLDEQ-8) followed a rigorous methodological process based on cross-cultural research guidelines consisting of three main phases: 1) forward and backward translation of original CLDEQ-8 into Chinese, 2) cross-cultural adaptation performed by medical advising committee, and 3) clinical validation and repeatability test of the translated questionnaire on Chinese SCL wearers. Rasch analysis was also performed to investigate the psychometric properties of C-CLDEQ-8.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!